If the oven is installed under a hob, the
distance between the worktop and the
top panel of the oven must be minimum
50 mm and the distance between the
worktop and the top of control panel
must be minimum 25 mm.
WIRING AND SAFETY OF
BUILT_IN OVEN
The instructions given below must be
followed without fail during wiring :
– The earthing cable must be connec-
ted via the screw with the earthing
mark. Supply cable connection must
be as shown in Figure 6. If there is
no earthed outlet conforming to regu-
lations in the installation environment,
call the Authorized Service immedia-
tely.
– The earthed outlet must be in close
vicinity of the appliance. Never use an
extension cord.
– The supply cable should not contact
the product's hot surface.
– In case of any damage to the supply
cable, make sure to call the Authori-
zed Service. The cable must be repla-
ced by the Authorized Service.
– Wiring of the appliance must be per-
formed by the Authorized Service.
H05VV-F type supply cable must be
used.
– Faulty wiring may damage the appli-
ance. Such a damage will not be co-
vered under the warranty.
– The appliance is designed to connect
to 220-240V~ electricty is different
than the value given above, call the
Authorized Service immediately.
– The Manucaturer Firm declares
that its bears no responsibility
whatsover for any kind of da-
mage and loss arising from not
complying
– Wiring of the appliance must be per-
formed by the Authorized Service.
The appliance is
– designed to connect to 220-240V~
electricity. If the mains electricity is
different than the value given, call the
Authorized Service immediately. The
appliance is designed for using with
plug ofor fixed connection to the ma-
ins. It is necessary that you install a
double pole switch between the pro-
duct and the electricity supply (ma-
ins), with a minimum gap of 3 mm bet-
ween the switch contacts. (20A rated,
delay function type).
–
3.4. GENERAL WARNING AND
PRECAUTIONS
Your appliance is produced in confor-
EN - 9
with
safety
norms!