2.2. Mechanical risks
Always connect the air ducts to the unit before plugging in its power supply. This ensures that the motors cannot be touched when the unit is running.
2.3. Electrical risks
The apparatus must not be powered on and operated by the end user as long as the product's protective channel and front panel are not fixed appropriately.
3. GENERAL INFORMATION
3.1. Technical specifications
Weight and dimensions
K
F
I
G
A
E
N
M
B
Electrical details
Description
InspirAIR
Top 300 (excluding options)
®
InspirAIR
®
Top 450 (excluding options)
InspirAIR
®
Top 300 (with internal preheating coil 11023486)
InspirAIR
Top 450 (with internal preheating coil 11023486)
®
3.2. List of accessories that can be connected to the unit
The InspirAIR
unit can operate with various accessories to be connected to its electronic board
®
Item
Description
11023470
Walter
connected sensor
®
11023480
InspirAIR
CO
remote control
®
2
11023479
InspirAIR
®
remote control
11023386
AldesConnect
Box
™
11017090
CO
probe
2
11026011
Two-speed remote control - Push button
11023225
InspirAIR
external heating coil
®
11023486
InspirAIR
Top
external heating coil
®
*
11023487
InspirAIR
Top external post-heating coil
®
*If this accessory is not installed, tick the relevant box on the product's manufacturer's plate with an indelible pen
(hexane-resistant) to confirm that it is not installed during commissioning (reference as example - action to be performed
for all models).
If this accessory is installed, refer to the relevant instructions and tick the appropriate box.
K
F
I
G
A
E
M
N
B
Power supply
230 V +/- 10%
50/60 Hz +/- 10%
Control/running
Wireless connection via AldesConnect
0-10 V
Control by IBus inlet
Dedicated control
Control by IBus inlet
17
M
N
B
Class
IP
Max. current
Class I
IP 22
(see §4.8 Electronic connections)
modem
Separate power supply (charger supplied)
™
Connected and supplied by the unit - HMI inlet
Connected and supplied by the unit - HMI inlet
Connected and supplied by the unit - USB inlet
item 11017180 Power supply 230 V/24 V
Connected and supplied by the unit - IBus inlet
Separate power supply, 230 V
Powered by the unit via relay on unit
Separate power supply, 230 V
InspirAIR
Top
®
Classic Premium
A (mm)
560
B (mm)
560
C (mm)
1045
D (mm)
1088
E (mm)
160
F (mm)
320
G (mm)
294
H (mm)
323
I (mm)
134
J (mm)
120
K (mm)
120
L (mm)
140
M (mm)
108
N (mm)
345
kg
28
41
Max. power
1.8 A
240 W
2.5 A
350 W
6.15 A
1,240 W
6.85 A
1,350 W
Electric power supply
Separate power supply
supplied with coil
EN