Maintenance and cleaning

Fault description
E 64 flashing Evaporator temperature <
minimum evaporator tem-
perature
E
flashing A permanent pressure switch
128
fault has occurred. A pressure
fault occurred multiple times
within a defined pressure
fault evaluation time.

14.2 Resetting the high limit safety cut-out

1 Reset button for high limit safety cut-out
The high limit safety cut-out protects the appliance from overhea-
ting. The electric emergency/booster heater is switched off when
the cylinder water temperature exceeds 87±5 °C.
Once the cause of the fault has been removed, press the reset
button of the high limit safety cut-out on the rod thermostat. To
do so, remove the appliance cover.
14.3 Motor overload relay
In the event of excessive thermal load on the compressor, the
motor overload relay switches the compressor off.
f Remove the cause.
After a short cooling period, the motor overload relay will restart
the compressor automatically.
58
| WWK 220-300 electronic
remedy
Check whether the evaporator is
clogged with deposits. If requi-
red, clean the evaporator with
clear water without cleaning
agents or other additives.
Check whether the air can flow
freely through the appliance.
Check whether the fan is blo-
cked or faulty. Replace the fan if
required.
Check the function and setting of
the expansion valve.
Check whether the appliance has
defrosted.
Check the relevant fault counter
and find the corresponding fault
code remedy: E 16 (high pressu-
re), E 32 (electrical wiring fault).
Once the cause of the fault has
been eliminated, reset the fault
code under menu option "Hd 1"
by pressing the "Rapid heat-up"
key.
1
15. Maintenance and cleaning
WARNING Electrocution
Prior to all work on the appliance, isolate it from the
power supply.
15.1 Removing the appliance cover
f Undo the screw (Torx) that fastens the control fascia and the
appliance cover to the appliance.
f Push the control fascia upwards.
f Remove the control fascia.
f A lead connects the operating controls to the appliance PCB.
If necessary, pull the plug from the back of the control fascia
to fully remove the control fascia.
f Carefully lift away the appliance cover and undo the earth
cable that runs from the appliance control panel to the cover.
Note
Refit the appliance cover after completing your work. See
chapter "Maintenance and cleaning / Fitting the appliance
cover").