Herunterladen Inhalt Inhalt Diese Seite drucken

Accessories; Declaration Of Conformity; Technical Data - Emerson AVENTICS CO1 Betriebsanleitung

Magnetspule mit leitungsdose
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Dispose of the product and the packaging in accordance with the applicable
u
national regulations.
12 Troubleshooting
If you cannot remedy a malfunction, get in touch with our contact address (con-
tact data: see back cover).
12.1 Basic requirements
General requirements for repair
• Never dismantle or convert the product (accident prevention, material pro-
tection).
• Do not carry out any unauthorized repair attempts (accident prevention, ma-
terial protection).
Permissible spare parts and reconditioning kits
• Only use spare parts and reconditioning kits from the online catalog (accident
prevention, material protection).
12.2 Notes on safety
To eliminate risks during troubleshooting, observe the notes on safety: see sec-
tion g 2.6.1. Notes on safety.
12.3 Procedure
Step 1: Check the system
In case of malfunctions, first check the system or the system part where the
u
product is installed. Check the following items:
• Are all connections connected to the product?
• Does the operating voltage comply with the requirements? See section
g 13. Technical data.
• Does the operating pressure comply with the requirements? See section
g 13. Technical data.
Step 2: Check the product

13 Technical data

This section contains an excerpt of the most important technical data. Further
technical data can be found in the online catalog.
General
Specifications
Ambient temperature
-10 °C to +50 °C
ATEX identification
See section g 5. Product description
Duty cycle
ED 100 %
Assembly
Specifications
Mounting orientation
Any
Assignment
Can be assembled into blocks
Electrics
Cross-version data
Specifications
Protection class according
IP 65
to EN 60529/IEC529
Cable diameter
6 to 8 mm
Cable cross section
0.5 to 1.5 mm
Voltage tolerance
At 50 Hz: -20 % / +10 %
At 60 Hz: -10 % / +20 %
Version specific data
R412000144
Voltage
24 V DC ±10 %
Current consump-
87 mA
tion
AVENTICS™ CO1 | R499050034-BAL-001-AI | English
2
R412000145
R412000146
R412000147
24 V AC
110/115 V AC
230 V AC
-
-
-
R412000144
Inrush current
-
Holding current
-
Standards and directives complied with
See declaration of conformity

14 Accessories

Information on spare parts and accessories can be found in the online catalog.

15 Declaration of conformity

The declaration of conformity can be found at the end of the instructions.
R412000145
R412000146
R412000147
287 mA
62 mA
30 mA
166 mA
36 mA
18 mA
18

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

R412000144R412000145R412000146R412000147

Inhaltsverzeichnis