3 609 929 985/1.0 | SEH312
5 Commissioning
5.6
Interface X 27: Resource
control
This interface is used to connect the X 7 in-
terface on the LTH12 servo amplifier for
Smart Tools.
1
20
Figure 7:Sub-D plug, 37-pin
Pin
Signal
System 200
Nomenclature
1
-
2
PRG4
3
NOKA
4
-
5
0 V
6
BMIO
7
SSR
8
-
9
PRG1
10
PRG3
11-14
-
15
NOK
16
-
17
CO
18
24VSE
19
0 V
20-24
-
25
TA
26
-
27
SLL
28
PRG2
29-32
-
33
IO
34
/SF
35
AE
36
24VSE
37
-
Table 8:
Electric Drives and Controls | Bosch Rexroth AG 19 /64
19
37
Signal
Description
System 300
Nomenclature
-
n.c.
Prog 3
Program selection, bit 3
NokAck
Acknowledgement of NOK
tightening
-
n.c.
0 V
Reference potential, hand-held
nutrunner
En
Option module ready (always
24 V)
Cw
Tightening start cw (tightening)
-
n.c.
Prog 0
Program selection, bit 0
Prog 2
Program selection, bit 2
-
n.c.
Nok
Tightening case not OK
-
n.c.
-
Color
24VSE
Power supply
0 V
Reference potential, hand-held
nutrunner
-
n.c.
-
Test sequence (SF reset)
-
n.c.
Ccw
Tightening start ccw (release)
Prog 1
Program selection, bit 1
-
n.c.
Ok
Tightening case OK
NF
System error (low active)
CyCmp
Sequence end
24VSE
Power supply
-
n.c.
I/O
Signal
form
-
-
I
24 V
I
24 V
-
-
-
I
24 V
I
24 V
-
-
I
24 V
I
24 V
-
-
O
24 V
-
-
O
24 V
-
24 V
-
-
-
-
I
24 V
-
-
I
24 V
I
24 V
-
-
O
24 V
O
24 V
O
24 V
-
24 V
-
-