Have all checks and work on electrical
parts performed by an qualified technician.
Note
The device must be switched off immedi-
ately in the event of a malfunction. The mal-
function must be eliminated before
switching the device on again.
If the malfunction cannot be corrected, the
device must be checked by the Customer
Service department.
Suction turbine does not start up
1. Check the socket and the power supply
fuse.
2. Check the mains cable and the mains
plug of the device.
3. Switch the device on.
Suction power decreases
1. Remove the blockages from the suction
nozzle, the suction pipe or the suction
hose.
2. Replace the filled dust bag (see chapter

Replace dust bag).

3. Check that the suction head and the dirt
receptacle are correctly seated.
4. Dedust the main filter (see chapter
Cleaning the main filter).
5. Check the seating of the filter and cor-
rect if necessary.
6. Replace the main filter (see chapter Re-
placing the main filter).
Escaping dust when vacuuming
1. Check the seating of the filter and cor-
rect if necessary.
2. Dedust the main filter (see chapter
Cleaning the main filter).
3. Replace the main filter (see chapter Re-
placing the main filter).

Disposal

At the end of its service life, the device is to
be disposed of in accordance with statutory
regulations.

Warranty

The warranty conditions issued by our rele-
vant sales company apply in all countries.
We shall remedy possible malfunctions on
your appliance within the warranty period
free of cost, provided that a material or
manufacturing defect is the cause. In a war-
ranty case, please contact your dealer (with
the purchase receipt) or the next author-
ised customer service site.
(See overleaf for the address)

Technical data

Electrical connection
Mains voltage
Phase
Power frequency
Nominal power
Maximum power
Protection class
Protection class
Maximum permissible
mains grid impedance
Dimensions and weights
Typical operating weight
Length x width x height
Filter area of main filter
Filter area of the H filter
Ambient conditions
Storage temperature
Device performance data
Container capacity
Vacuum (with pressure re-
lief valve)
Air quantity
Suction hose connection
Nominal width of the suc-
tion hose
Determined values in acc. with EN
60335-2-69
Hand-arm vibration value m/s
Uncertainty K
Sound pressure level L
Uncertainty K
English
V
~
Hz
W
W
Ω
kg
mm
2
m
2
m
°C
l
kPa
l/s
2
2
m/s
dB(A) 79
pA
dB(A) 2
pA
220-
240
1
50-60
3150
3600
IPX4
I*
0.195+
j0.122
81
1020 x
680 x
1890
2.24
3.5
-10-40
100
25.4
3x 74
NW
DN70
DN40/
50/70
< 2.5
0.2
21