EN
Name
Telephone
Fault
Low salt
01.07.14
10:45:21
Info -> Help
68
8
Operation
Please note that there is a separate manual for the
Multiblock module and connection set DN 32/32.
8.1
Note display
The appearance of a red triangle indicates that a
note exists.
Press the red triangle to display the note.
8.2
Refilling the regenerative
Refill regenerative when Low salt is indicated on
the display.
All commonly available regeneration salts (salt
tablets in accordance with DIN EN 973 type A, e.g.
Clarosal or Sanisal/Sanitabs) can be used.
Open the cover (2). Fill the regenerative container
(3) with salt.
Press the button until the Low salt message disap-
pears.
It is important that no dirt gets into the regenerative
container (3) when refilling (if necessary, clean the
regenerative packages before use).
Clean the regenerative container (3) with drinking
water if dirt does get into the unit.
2
3
6