Measurement
Cuff pressure 0 – 299 mmHg,
range
systolic 40 – 250 mmHg,
diastolic 40 – 250 mmHg,
Pulse 40 –199 beats/minute
Display accuracy
Systolic ± 3 mmHg, diastolic ± 3 mmHg,
pulse ± 5 % of the value shown
Measurement
Max. permissible standard deviation accord­
inaccuracy
ing to clinical testing: systolic 8 mmHg /
diastolic 8 mmHg
Memory
2 x 50 memory spaces
Dimensions
L 156 mm x W 105 mm x H 74,5 mm
Weight
Approx. 315 g (without batteries)
Cuff size
24 to 36 cm
Permissible oper­
+10 °C to + 40 °C, 40 – 85 % relative air
ating conditions
humidity (non­condensing)
Permissible stor­
­10 °C to + 60 °C, 10 – 90 % relative air humid­
age conditions
ity, 800 –1050 hPa ambient pressure
Power supply
4 x 1,5 V
Battery life
For approx. 300 measurements, depend­
ing on the blood pressure level and/or pump
pressure
Accessories
Instruction for use, 4 x 1.5 V AA batteries,
storage pouch
Classification
Internal supply, IPX0, no AP or APG, continu­
ous operation, type BF applied part
Technical information is subject to change without notification
to allow for updates.
All manuals and user guides at all-guides.com
AA batteries
• This unit is in line with European Standard EN 60601­1­2
and is subject to particular precautions with regard to elec­
tromagnetic compatibility (EMC). Please note that portable
and mobile HF communication systems may interfere with
this unit. More details can be requested from the stated Cus­
tomer Service address or found at the end of the instructions
for use.
• This device is in line with the EU Medical Devices Directive
93/42/EC, the "Medizinproduktegesetz" (German Medi­
cal Devices Act) and the standards EN 1060­1 (non­inva­
sive sphygmomanometers, Part 1: General requirements),
EN 1060­3 (non­invasive sphygmomanometers, Part 3: Sup­
plementary requirements for electro­mechanical blood pres­
sure measuring systems) and IEC 80601­2­30 (Medical elec­
trical equipment – Part 2 – 30: Particular requirements for the
safety and essential performance of automated non­invasive
blood pressure monitors).
• The accuracy of this blood pressure monitor has been care­
fully checked and developed with regard to a long useful life.
If using the device for commercial medical purposes, it must
be regularly tested for accuracy by appropriate means. Pre­
cise instructions for checking accuracy may be requested
from the service address.