5
MOUNTING
5
Mounting
en
6
Electrical installation
16
O P E R A T I N G I N S T R U C T I O N S | WTB4-3P2100S79 Monitoring
Mount the sensor using a suitable mounting bracket (see the SICK range of accesso‐
ries).
Figure 6: Preferred direction of the object relative to the sensor
Note the preferred direction of the object relative to the sensor, cf.
page
16.
Note the maximum permissible tightening torque for the sensor of 0.8 Nm.
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
–
Male connector connection: Pin assignment
Only apply voltage and switch on the voltage supply once all electrical connections have
been established.
Explanation of the connection terminology used in the following tables:
BN = brown
BU = blue
BK = black
Q = digital output
L+ = supply voltage (U
)
V
M = ground
DC: 10 ... 30 V DC,
see „Technical specifications", page 20
Table 5: DC
1 = BN
3 = BU
4 = BK
WTB4-3P2100S79
see figure 6,
+ (L+)
- (M)
Q
8027117.1COU/2022-02-14 | SICK
Subject to change without notice