120
x

ELECTRICAL CONNECTION

• The mains voltage must match that given on the ratings label
inside the hood itself. If the hood has a power plug, connect the
hood to an easily accessible regulatory power socket. If it does
not (direct connection to the mains), or the socket is not easily
accessible, install a two-pole regulatory switch to enable total
disconnection from the mains in case of category III overvoltage,
as required by the installation regulations.
!
LED Replacement
For replacement contact technical support.
GB
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 120 mm.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Cut a hole ø 125 mm in any shelf that may be positioned over
125
125
the hood.
• Connect the flange to the outlet on the shelf over the hood
by using a flexible or rigid pipe ø120 mm.
• Fix the pipe in position using sufficient pipe clamps.
• Fix the air outlet grid x on the recirculation air outlet.
This material is not supplied.
• Ensure that the activated charcoal filters have been
inserted.