Use the reference number found under
Data".
Assembly
WARNING:
When assembling or inserting the extraction filter
as well as the carbon filter, the appliance must not
be connected to the mains.
Failure to use the mounting fixtures may lead to a
risk of electric shock.
CAUTION:
Before mounting, check that the wall has enough
load capacity to bear the cooker hood.
When drilling the holes in the wall always make
sure that no existing electrical cables or other ob-
jects are damaged.
Make sure that the ventilation slots are clear of
obstacles and are not covered.
NOTE: Recommendations for preparation work
When installing, ask another person to assist.
Wear protective gloves to prevent injuries from
any sharp edges.
Drilling dimensions
[03]
"Technical
unit mm
[04]
[05]
Determine the position of the cooker hood central-
ly above the cooking area in accordance with the
specified safety distances.
Totally 9x mounting holes with a diameter of approx.
8 mm are necessary for the wall mounting. Insert the
supplied dowels [08].
Mark the holes required for wall mounting as
shown in the drawing. First specify the extension
length of the shaft cover for the position of the
bracket [04] at the upper shaft end. Check the
markings with a spirit level!
Fix the bracket [05] for the housing with three
screws ST4x30mm [09] and the brackets [03] and
[04] at the pre-marked positions, each with two
screws ST4x30mm [09].
Before inserting the hood, affix the non-return
valves [07] by gently bending them from above
onto the exhaust duct.
41