Range is reducing
• There are too many interfering sources (e.g. metal constructions) between the handset and
the door unit. Place the handset at a different place for a stronger signal.
• The batteries are low. Replace the door unit batteries or charge the handset.
Out of reach indicator is always on
• The door unit is not getting powered. Replace the batteries or check the power adapter of
the door unit.
• The back door on/off select dipswitch (21) is set on the 'ON' position. Set the dipswitch on
'OFF'.
Electric door opener is not functioning
• The Door open on/off select dipswitch (20) is set on the 'OFF' position. Set the dipswitch on
'ON'.
• You haven't used a power adapter for the door unit. Connect the power adapter.
• The connecting clamps are incorrectly connected. Connect them correctly.
The electric door opener sometimes functions and sometimes not.
• When you operate the electric door opener, in the display next to the battery indicator you
will see the symbol of a closed door. Please do not hang up until you see that this symbol
has changed into an open door.
Intercom is not functioning
• The ID code is not cloned correctly to the other handsets. Repeat the cloning procedure.
• The battery is (almost) empty. Charge the battery of the handset.
• The different handsets are set to different channels. Set the handsets on the same channel
and repeat the cloning procedure.
Do you still have questions, please check out www.marmitek.com
10. TECHNICAL DATA
Handset
Power:
Charger:
Power consumption:
Bell sound:
Channels:
Dimensions:
Door unit
Range
Power
16
4,8v Ni-mH battery set
9V 300mA
Stand-by
25 mA
Active
50 mA
3 Programmable tunes
1,2,3,4.
52x142x32mm
Up to 150m in free field,
up to 50m through walls and ceilings
Battery (4x AA alkaline)
© MARMITEK