Technical Data
6.4.
general Technical data
Control functions
T he valve seat is always closed against
the medium flow
Control function A
Closed by spring force in rest position
Control function B
Opened by spring force in rest position
Control function I
Actuating function via reciprocal
pressurisation
(not for actuator size ø 50 mm in
combination with Type 8696)
actuator sizes
ø 50 mm
ø 70 mm
ø 90 mm
materials
Valve housing
316L
Actuator
PPS and stainless steel
Sealing elements
FKM and EPDM
Spindle sealing
PTFE-V rings with spring compensation
(with silicone grease)
Control cone
Control cone with PTFE seal
Steel/steel seal
Spindle
1.4401 / 1.4404
Spindle guide
PEEK
All manuals and user guides at all-guides.com
Type 2301
Connections
Control air connection
prepared for direct connection
Medium connection
Socket: G ½ – G 2 (NPT, RC on request)
Welded connection: as per ISO 4200,
DIN 11850 R2
Flange: as per DIN 2634,
ANSI B16.5 Class 150, JIS 10K
Other connections on request
media
Control medium
neutral gases, air
Flow media
Water, Alcohol, Fuel,
Hydraulic liquids, Saline solutions,
Lyes, Organic solvents
installation position
any position, preferably with the actuator
face up
protection class
IP67 in accordance with IEC 529/EN 60529