SAFEMASTER
Light Curtain Controller With Selectable Operating Modes
BH 5902/01MF2

Block Diagram

S21 S22 S24 S23
A1+
A2
S12 S14
PTC
galvanic separation
monitoring
logic 1
galvanic
separation
K1
K1
run1
48
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.
S31 S32 S34 S33
M2
S41 S42 S44 S43
M1
K1
monitoring
logic 2
K2
galvanic
separation
K2
K2
run2
X44
58
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• To connect max.:
- 3 light curtains 2-channel or
- 2 light curtains 2-channel and 2 muting sensors 1-channel or
- 1 light curtain 2-channel and 4 muting sensors 1-channel or
- 2 light curtains 2-channel and key switch for stepping operation
- Additionally: Start button and machine contact with line fault detection
• Broken wire detection on light curtain input
• Outputs:
- 3 NO or 2 NO and 1 NC
- 2 Semiconductor outputs, protected against short circuit and overload
• Multifunction device, different functions selectable by rotational
switches:
- Protective operation e.g. light curtains
- Protective operation with muting, e.g. conveyors
* Signal sequence of muting sensors can be selected
* Override function via start button
13 23 33
- Stepping operation e.g. on presses
* Optionally with key switch
* 1, 2 or 3 steps possible
* Setting of number of step possible via selector switch
• Suitable to connect light curtains of type 4 or selftesting light curtains
type 2 according to IEC/EN 61 496-1, crossfault monitoring in the light
curtain
• With under- and overvoltage detection and indication
• Reaction time: max. 30 ms
• LED indication for RUN and Channel 1,2
• Width 45 mm

Approvals and Markings

14 24 34
M7958

Applications

• Protection of men and machines e.g. presses and conveyors

Indicators

Lower green LEDs
K1, K2:
Upper yellow LED
run 1:
Semiconductor output 48: -
23
Canada / USA
-
On, when K1 and K2 are energized
-
Permanent on, when relay K1 and K2 are energized
-
Flashes with 1 Hz when the unit waits for the start
signal after fault free operation (power up of the unit)
-
Flashes fast with approx. 3 Hz when the start button
is pressed and all conditions for an override are
fulfilled during muting
-
Flashes fast with approx. 3 Hz when at stepping
operation the unit waits for interruption of the
light curtain
-
Flashes with failure code to indicate normal indication
states that disable the energisation of the output
relays (e.g. after not allowed interruption of the
light curtain) until the start button is pressed
-
Flashes with failure code to indicate
special failures (e.g. undervoltage)
Off, when unit is on special failure mode
-
Normally off when relays K1 and K2 are energized
-
Continuously on, when unit in muting mode
-
Shows the same failure codes as LED
run 1 (except on special failures)