FAMILY
10
11
12
9
8
7
6
6
5
4
6
3
2
1
M
AC
15.2
[EN] - Hydraulic circuit
AF
Cold water inlet
AC
Hot water outlet
M
Heating delivery
R
Heating return
1
Safety valve
2
Drain valve
3
Automatic by-pass
4
Filling tap
5
Filling solenoid
6
Non-return valve
7
DHW NTC probe
8
Pressure transducer
9
Manual air vent valve
10
Delivery NTC probe
11
Limit thermostat
12
Primary heat exchanger
13
Return NTC probe
14
Expansion vessel
15
Lower air vent valve
16
Circulator
17
Water gauge
18
Three-way valve
19
Flow regulator
20
Flow switch
21
DHW filter
[EN] - Residual head of circulator
The boiler is equipped with a high efficiency
modulating circulator already hydraulically
and electrically connected, whose useful avail-
able performance is indicated in the graph.
The modulation is managed by the board
through the PUMP DUTY CYCLE - access
level INSTALLER.The circulator is factory set
with discharge head of 7 meters. The boiler is
equipped with an anti-blocking system which
starts up an operation cycle after every 24
hours of disuse in any operating status.
b
The
"anti-locking"
function
only activated when the boiler is
electrically powered.
a
It is strictly forbidden to operate the
circulator without water.
Where there is the need to use a different
curve, the desired level can be selected on
the circulator.
Variable speed circulator
The modulating circulator function (applica-
ble only to the boiler circulator and not to the
circulators of any external devices connected
108
2
13
14
15
16
17
18
19
20
21
R
AF
[HU] - Hidraulikus kör
Hideg víz-bemenet
Meleg víz-kimenet
Fűtés előremenő
Fűtési visszatérő
Biztonsági szelep
Leeresztő szelep
Automatikus by-pass
Feltöltő csap
Feltöltő mágnesszelep
Visszafolyást gátló szelep
HMV NTC szonda
Nyomástranszduktor
Manuális légtelenítő szelep
Előremenő NTC érzékelő
Határoló termosztát
Elsődleges hőcserélő
Visszatérő NTC érzékelő
Tágulási tartály
Alsó légtelenítő szelep
Keringtető szivattyú
Hidrométer
Háromutas szelep
Áramlásszabályozó
Áramlásszabályozó
Használati melegvíz-szűrő
(e.g. booster circulator)) is only active in the
heating function. The circulator always oper-
ates at maximum speed when switching the
three-way to DHW. Through the PUMP DUTY
CYCLE parameter it is possible to choose
between:
1 - VARIABLE SPEED CIRCULATOR WITH
PROPORTIONAL MODE (41 <= PUMP
DUTY CYCLE <= 100): the boiler board
determines which flow rate curve to adopt
according to the instantaneous power deliv-
ered by the boiler.
2 - VARIABLE SPEED CIRCULATOR WITH
CONSTANT ∆T MODE (2 <= PUMP
is
DUTY CYCLE <= 40): the installer sets the
∆T value to be maintained between outlet
and return (e.g .:by entering a value = 10,
the circulator speed will change to achieve
a system flow rate with the aim of maintain-
ing the ∆T of 10°C upstream and down-
stream of the exchanger).
3 - CIRCULATOR IN MAXIMUM FIXED
SPEED MODE (PUMP DUTY CYCLE =
1): the circulator, when activated, always
operates at maximum speed. Used on
systems with high pressure drop where
700
650
600
550
500
450
400
350
300
250
200
150
100
50
0
0
100
200
300
400
500
Residual head of circulator (Fig. 3)
EN
A
Residual head (mbar)
Flow rate (l/h)
A keringető maradék fejmagassága (3. ábra)
A
HU
Maradék emelőnyomás
Hozam (l/h)
(mbar)
Presiune reziduală a pompei de circulaţie (Fig. 3)
A
RO
Presiune reziduală
Debit (l/h)
(mbari)
Restförderhöhe der Umlaufpumpe (Abb. 3)
DE
A
Restförderhöhe (mbar)
Durchsatz (l/h)
[RO] - Circuit hidraulic
Intrare apă rece
Ieşire apă caldă
Tur încălzire
Retur încălzire
Supapă de siguranţă
Supapă de evacuare
By-pass automat
Robinet de umplere
Solenoid umplere
Supapă de sens
Sondă NTC ACM
Traductor de presiune
Vană de evacuare aer manuală
Sondă NTC tur
Termostat limită
Schimbător principal de căldură
Sondă NTC retur
Vas de expansiune
Supapă inferioară de aerisire
Pompă de circulaţie
Hidrometru
Vană cu trei căi
Flow regulator
Fluxostat
Filtru ACM
it is necessary to make the most of the
boiler discharge head in order to ensure
sufficient circulation (system flow rate at
maximum speed less than 600 litres per
hour).
Used in the presence of hydraulic separa-
tors with high flow rates in the downstream
circuit. Operationally:
enter the PUMP DUTY CYCLE parameter
set the value = 1
EN
CONFIGURATIONS RECOMMENDED BY THE MANUFACTURER
OUTDOOR TEMPERATURE
SENSOR YES
(THERMOREGULATION)
LOW
ΔT constant
TEMPERATURE
(5 ≤ PUMP DUTY CYCLE ≤ 7)
(floor)
HIGH
TEMPERATURE
ΔT constant
(radiators without
(15 ≤ PUMP DUTY CYCLE ≤ 20)
thermostatic valves)
HIGH
TEMPERATURE
ΔT constant
(radiators with
(15 ≤ PUMP DUTY CYCLE ≤ 20)
thermostatic valves)
C
85 (default)
60
41
600
700
800
900
1000
1100
1200
B
Portata impianto [l/h]
15.3
B
C
7-metre circulator (factory setted)
B
C
7 méteres keringtető szivattyú (gyári
beállítás)
B
C
Pompă de circulaţie la 7 m (setată în
fabrică)
B
C
7-Meter Umlaufpumpe (Werkseinstellung)
[DE] - Wasserkreislauf
Kaltwassereingang
Warmwasserausgang
Heizungsvorlauf
Heizungsrücklauf
Sicherheitsventil
Ablassventil
Automatischer Bypass
Füllventil
Füllmagnetventil
Rückschlagventil
BWW-NTC-Fühler
Druckaufnehmer
Manuelles Entlüftungsventil
Vorlauf-NTC-Fühler
Grenzthermostat
Primärwärmetauscher
Rücklauf-NTC-Fühler
Ausdehnungsgefäß
Unteres Entlüftungsventil
Umlaufpumpe
Hydrometer
3-Wege-Ventil
Flussregler
Strömungswächter
BWW-Filter
4 - EXCEPTIONAL USE OF A STANDARD
NON-SPEED ADJUSTABLE CIRCULA-
TOR (PUMP DUTY CYCLE = 0): mode
used in exceptional cases in which a tra-
ditional UPS circulator is to be used in the
boiler.
OUTDOOR TEMPERATURE
SENSOR
(NO THERMOREGULATION)
PROPORTIONAL
(PUMP DUTY CYCLE = 85)
PROPORTIONAL
(PUMP DUTY CYCLE = 85)
PROPORTIONAL
(PUMP DUTY CYCLE = 60)
100
1300
1400
1500
3