Spezifikationen
Name
epc1202TrapCtrl
epc1202TrapIPIndex
epc1202TrapAddr
epc1202portNumber
epc1202PortIndex
epc1202PortName
epc1202PortState
epc1202PortSw itchCount
epc1202PortStartupMode
epc1202PortStartupDelay
epc1202PortRepow erTime
epc1202PortResetDuration
epc1202ActivePow erChan
epc1202Pow erIndex
epc1202ChanStatus
epc1202AbsEnergyActive
epc1202Pow erActive
epc1202Current
epc1202Voltage
epc1202Frequency
epc1202Pow erFactor
epc1202Pangle
epc1202Pow erApparent
epc1202Pow erReactive
epc1202AbsEnergyReactive
epc1202AbsEnergyActiveResetta
ble
epc1202AbsEnergyReactiveReset
table
Expert Power Control 1202/1292
OID
Description
.43.1.1.1.1.0
0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3
.43.1.1.1.2.1.1.x
A unique value, greater than zero, for each receiver slot.
.43.1.1.1.2.1.2.x
DNS name or IP address specifying one Trap receiver slot. A port can
optionally be specified: 'name:port' An empty string disables this slot.
.43.1.3.1.1.0
The number of Relay Ports
.43.1.3.1.2.1.1.x
A unique value, greater than zero, for each Relay Port.
.43.1.3.1.2.1.2.x
A textual string containing name of a Relay Port.
.43.1.3.1.2.1.3.x
current state of a Relay Port
.43.1.3.1.2.1.4.x
The total number of sw itch actions ocurred on a Relay Port. Does not
count sw itch commands w hich w ill not sw itch the ralay state, so just
real relay sw itches are displayed here.
.43.1.3.1.2.1.5.x
set Mode of startup sequence (off, on , remember last state)
.43.1.3.1.2.1.6.x
Delay in sec for startup action
.43.1.3.1.2.1.7.x
Delay in sec for repow er port after sw itching off
.43.1.3.1.2.1.8.x
Delay in sec for turning Port on again after Reset action
.43.1.5.1.1.0
Number of suppported Pow er Channels.
.43.1.5.1.2.1.1.x
Index of Pow er Channel entries
.43.1.5.1.2.1.2.x
0 = data not active, 1 = data valid
.43.1.5.1.2.1.3.x
Absolute Active Energy counter.
.43.1.5.1.2.1.4.x
Active Pow er
.43.1.5.1.2.1.5.x
Actual Curent on Pow er Channel.
.43.1.5.1.2.1.6.x
Actual Voltage on Pow er Channel
.43.1.5.1.2.1.7.x
Frequency of Pow er Channel
.43.1.5.1.2.1.8.x
Pow er Factor of Channel betw een -1.0 and 1.00
.43.1.5.1.2.1.9.x
Phase Angle betw een Voltage and L Line Current betw een -180.0 and
180.0
.43.1.5.1.2.1.10.x
L Line Mean Apparent Pow er
.43.1.5.1.2.1.11.x
L Line Mean Reactive Pow er
.43.1.5.1.2.1.12.x
Absolute Reactive Energy counter.
.43.1.5.1.2.1.13.x
Resettable Absolute Active Energy counter. Writing '0' resets all
resettable counter.
.43.1.5.1.2.1.14.x
Resettable Absolute Reactive Energy counter.
Type
Acc.
Integer32
RW
Integer32
RO
OCTETS
RW
Integer32
RO
Integer32
RO
OCTETS
RW
INTEGER
RW
Integer32
RO
INTEGER
RW
Integer32
RW
Integer32
RW
Integer32
RW
Unsigned32
RO
Integer32
RO
Integer32
RO
Gauge32
RO
Integer32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Integer32
RO
Integer32
RO
Integer32
RO
Integer32
RO
Gauge32
RO
Gauge32
RW
Gauge32
RO
© 2022 GUDE Systems GmbH