Technical data

Sensing range max.
Light spot diameter/distance
Supply voltage U
B
Ripple
Current consumption
Output current I
max.
Max. response time
Switching frequency
Enclosure rating
5)
Protection class
Circuit protection
Ambient operating temperature
1)
16 VDC to 30 VDC, without load
2)
10 VDC to 16 VDC, without load
3)
Signal transit time with resistive load in switching mode. Deviating values possible in COM2 mode.
4)
With a light/dark ratio of 1:1 in switching mode. Deviating values possible in IO-Link mode.
5)
Pursuant to EN 60529
6)
Replaces IP69 K pursuant to ISO 20653: 2013-03
A = U
-connections reverse polarity protected
7)
B
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
8)
Do not bend cables below 0°C.
12.1

Dimensional drawings

8020358.14CS | SICK
Subject to change without notice
24,6
24,6
Ø 5,2
3
1
2
10
12,9
12,9
6,4
5
Figure 6: Dimensional drawing 1, cable
Center of optical axis, sender
1
Center of optical axis, receiver
2
Fixing hole, Ø 5.2 mm
3
Connection
4
WSE26P
0 m ... 60 m
Ø 90 mm (8 m)
DC 10 ... 30 V
≤ 5 V
SS
≤ 30 mA
1)
< 50 mA
2)
≤ 100 mA
500 µs
3)
1000 Hz
4)
see table
1:
x4, xH, x5, xI: IP66,
IP67, IP69
6)
x9, xB: IP65
III
A, B, C, D
7)
–40 °C ... +60 °C
48,1
1
40
44,2
3
7,1
4
10,8
M12
25
8,1
38,8
53,3
6
7
Figure 7: Dimensional drawing 2, male con‐
nector
TECHNICAL DATA
WSE26I
0 m ... 60 m
Ø 110 mm (8 m)
DC 10 ... 30 V
≤ 5 V
SS
≤ 30 mA
1)
< 50 mA
2)
≤ 100 mA
500 µs
3)
1000 Hz
4)
see table
1:
x4, xH, x5, xI: IP66,
IP67, IP69
6)
x9, xB: IP65
III
A, B, C, D
7)
–40 °C ... +60 °C
8)
48,1
24,6
24,6
Ø 5,2
3
63,9
2
19,7
44,2
4
M12
6,3
53,3
5
6
12
8)
40
3
7,1
10,8
25
8,1
39
7
13