► Mount the prosthetic knee joint as shown in Fig. 

6.2.6 Mounting the proximal adapters

► Mount the proximal adapters as shown in Fig. 

6.2.7 Preparing the prosthetic socket for the lock slide

► Prepare the prosthetic socket for mounting the lock slide as shown in Fig. 
note the following points:
Positioning at the optimum height for the patient's hand 
Laying the perlon cable in the prosthetic socket, in a straight line from the prosthetic knee
joint to the lock slide 
Lamination plate secured against rotation in the laminate 
In and out holes for the perlon cable with sufficient spacing from the prosthetic knee joint and
lock slide for reliable lock function 
Plastaband as protection for the thread on the lamination plate while laminating 
Greased perlon cable dummy for making a channel centred in the laminate 

6.2.8 Marking the prosthetic socket

► Mark the prosthetic socket as shown in Fig. 

6.2.9 Positioning the prosthetic socket

► For positioning the prosthetic socket, note Fig. 
low.
Thomas test
► Place the flat hand 
► Instruct the recumbent patient 
► Bring the residual limb to hip flexion until the hollow back disappears.
► Extend the residual limb slowly by pushing it until the pressure of the spine on the back of
your hand diminishes.
► In this residual limb position, measure angle α of the flexion malposition.
Socket flexion
► Based on angle α, determine the optimum socket flexion β 
► Set the socket flexion β so that the lateral socket reference point 
erence line.
INFORMATION: If the socket reference point 
line with the adapters that are installed, special adapters have to be used (
adapters).
Socket adduction
► Based on the socket length, determine the required angle γ 
reconcile this with a possible residual limb malposition.
► Set the socket adduction γ so that the frontal socket reference point 
reference line.
INFORMATION: If the socket reference point 
line with the adapters that are installed, special adapters have to be used (
adapters).

6.2.10 Shortening the tube adapter

CAUTION
Incorrect processing of tube
Fall due to damage to the tube
Do not clamp the tube into a vice.
For shortening the tube, use only a tube cutter.
48 | Ottobock
2
4
2
under the lumbar spine.
1
to flex the contralateral knee joint and hip joint.
18
on page 14.
19
on page 14.
1
3
21
on page 15 for positioning.
22
on page 16 and the instructions that fol­
3
according to the illustration.
5
cannot be positioned on the alignment reference
9
cannot be positioned on the alignment reference
20
on page 15 and
5
6
4
lies on the alignment ref­
6
 examples of
7
for socket adduction, and
8
lies on the alignment
10
 examples of

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Puro spring 3r120-kdPuro spring 3r120-hd

Inhaltsverzeichnis