syslog server set "{dns_name}"
syslog server show
system
system beeper manual set {OFF=0|ON=1}
{millisec}
system beeper manual show
system restart
system fabsettings
system bootloader
system flushdns
system uptime
system name show
system version show
system display {disp_num} default extsensor
{port_num} {sen_type} set {sen_field}
system display {disp_num} default linesensor
{line_num} set {sen_field}
system display {disp_num} default set
{BLANK=0,LOCAL_TIME=1,UTC_TIME=2}
system display {disp_num} default show
system display default hash set "{data}"
system display default hash show
system {SWITCH_PORT=0} events set {OFF=0|
ON=1}
system {SWITCH_PORT=0} events show
system {SWITCH_PORT=0} events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E
VT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER=5,E
VT_DISPLAY=6,EVT_CONSOLE=7,EVT_MQTT=8}
"
system {SWITCH_PORT=0} events type show
system {SWITCH_PORT=0} events mqtt retain set
{OFF=0|ON=1}
system {SWITCH_PORT=0} events mqtt retain
show
system panel enabled set {OFF=0|ON=1}
system panel enabled show
system panel port all set {OFF=0|ON=1}
system panel port all show
system sensor {VSYS=0|VAUX=1|VMAIN=2|
TCPU=3} show
timer
timer enabled set {OFF=0|ON=1}
timer enabled show
timer syslog facility set {0..23}
timer syslog facility show
timer syslog verbose set {0..7}
timer syslog verbose show
timer {rule_num} enabled set {OFF=0|ON=1}
timer {rule_num} enabled show
timer {rule_num} name set "{name}"
timer {rule_num} name show
timer {rule_num} {FROM=0|UNTIL=1} set "{yyyy-
mm-dd}"
timer {rule_num} {FROM=0|UNTIL=1} show
timer {rule_num} trigger jitter set {0..65535}
timer {rule_num} trigger jitter show
timer {rule_num} trigger random set {0..100}
timer {rule_num} trigger random show
timer {rule_num} trigger {HOUR=0|MIN=1|SEC=2|
DAY=3|MON=4|DOW=5} set "{time_date_list}"
timer {rule_num} trigger {HOUR=0|MIN=1|SEC=2|
DAY=3|MON=4|DOW=5} show
Expert Power Control 8221/8226
sets address of syslog server
show s address of syslog server
enters cmd group "system"
manually sets beeper w ith optional duration
show s beeper state
restarts device
restore fab settings and restart device
enters bootloader mode
flush DNS cache
number of seconds the device is running
show s device name
show s actual firmw are version
show s external sensor
show s energy line sensor
show s other contents
show s default setting for display
sets hashed display setting
show s hashed display setting
enable global events
show s if global events enabled
enables different event types
show s w hat event types are enabled
sets mqtt retain
show s if mqtt retain set
blocks panel buttons w hen not enabled
show s if panel buttons are enabled
enable siw tch all relays from panel buttons
show s if siw tch all relays from panel buttons
enabled
show s internal sensors if model supports it
enters cmd group "timer"
enables timer functions
show s if timer a enabled
sets facility level for timer syslog
show s facility level for timer syslog
sets verbose level for timer syslog
show s verbose level for timer syslog
enables rule
show s if rule is enabled
sets name of rule
show s name of rule
sets date range of rule
show s date range of rule
sets jitter for rule
show jitter of rule
sets probability for rule
show s rule probability
sets time date list
show s time date list