MALFUNCTION
 The appliance
does not work at
all.
 LED does not
work at all.
 Light is on but
motor does not
work
 The motor
smells doubtful
 Smear of oil
 Appliance
vibrates
 Insufficient
extracting
capacity
 Light does not
work
 Appliance is
unstable
If the hood does not work properly and/or you can hear increased operating noise, check the
 incorrect dimension of the air duct.
 obstruction in the air duct.
 the diameter of the air duct from hood to wall-box inclusive should be 150 mm;
 if you have installed a fly screen on the wall-box, the air vent may be obstructed.
 if the cover panel of the wall box is equipped with firm and slanted slats, the air vent
 install a cover panel with moveable slats, which do not obstruct the air vent.
 check condition and cleanliness of the filters.
 check if the air which is extracted by the hood is replaced to avoid negative pressure.
 when you run your appliance in recirculating mode, check if the carbon filter has been
Downloaded from
www.Manualslib.com

8. TROUBLE SHOOTING

POSSIBLE CAUSE
 The plug of the appliance is not
connected to the socket.
 The plug has become loose.
 The socket is not supplied with
energy.
 The fuse is switched off.
 ventilation damper blocked
condenser
 motor mounting defective
 motor defective
 one-way valve is leaky
 connection base chimney-
telescopic chimney is leaky
 motor not properly fixed
 hood not properly fixed
 too much distance hood-hob
 too much draught because of
open doors and/or windows
 illuminate is defective
 mounting rail is not firmly fixed
 screws are not firmly tightened
otherwise the capacity of the motor may be decreased.
Check by removing the fly screen.
may be obstructed. Check by removing the cover panel.
replaced on time ( min. every 3-6 months ).
manuals search engine
defective
schedule below:
76
MEASURE
 Check the
corresponding socket
by connecting it with
another appliance.
 Check the fuse.
 The voltage is too low.
Compare the data on
the model plate with
the data of your energy
supplier.
 remove blockage
 replace condenser
 replace motor
 replace motor
 seal the valve
 seal the connection
with a suitable material
 fix motor properly
 fix hood properly
 lower position of hood
 close the
doors/windows
 Contact the after sales
service.
 fix mounting rail
properly
 tighten the screws

Werbung