DH 5 SDS-max
Inserting the tools
t^okfkd>
_ÉÑçêÉ=éÉêÑçêãáåÖ=~åó=ïçêâ=çå=íÜÉ=ÉäÉÅíêáÅ=
éçïÉê=íççäI=éìää=çìí=íÜÉ=ã~áåë=éäìÖK
`^rqflk>
rëÉÇ=áåëÉêíáçå=íççäë=ã~ó=ÄÉÅçãÉ=ÜçíK=
tÉ~ê éêçíÉÅíáîÉ=ÖäçîÉë>
Clean and lightly grease the shaft
of the insertion tool.
Check dust cap.
– Clean dirty cap.
– Replace defective dust cap.
Insert insertion tool and turn until it locks.
Check lock by pulling on the insertion tool.
Removing the tools
t^okfkd>
_ÉÑçêÉ=éÉêÑçêãáåÖ=~åó=ïçêâ=çå=íÜÉ=ÉäÉÅíêáÅ=
éçïÉê=íççäI=éìää=çìí=íÜÉ=ã~áåë=éäìÖK
`^rqflk>
rëÉÇ=áåëÉêíáçå=íççäë=ã~ó=ÄÉÅçãÉ=ÜçíK=
tÉ~ê éêçíÉÅíáîÉ=ÖäçîÉë>
Pull locking sleeve backwards (1.).
Remove insertion tool (2.).
Setting the chisel position
The chisel can be adjusted in 12 positions
(moved 30° in each case).
Pull rotary ring for chisel setting forwards
and hold (1.).
Turn chisel until the chisel is at the required
angle (2.).
Release rotary ring for chisel setting (3.).
Switching on the power tool
Without locking the switch:
Press and hold down the switch.
Switch off the machine:
Release the switch.
15