5.2 Tools and materials
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance
with the current standards and regulations. The following figure illustrates the minimum equipment needed by the installer.
5.3 Cable list and minimum thickness
Connections
Control panel power supply 230V
Motor power supply 230V
Flashing light
Photocell transmitters
Photocell receivers
Accessories power supply
Control and safety devices
Antenna
N.B.: If the cable length differs from that specified in the table, then you must determine the proper cable diameter in the basis of
the actual power draw by the connected devices and depending on the standards specified in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power
draw and distances.
When connecting products that are not specified in this manual, please follow the documentation provided with said products.
5.4 Standard installation
1) A18230 operator
2) Control panel
3) Reception antenna
4) Flashing light
5) Selector switch
6) Photocells
7) Electric cable junction box
8) Mechanical gate stops
2
Length of cable
Type of cable
FROR CEI
20-22
CEI EN
50267-2-1
RG58
6
4
3
5
7
Length of cable
1 < 10 m
10 < 20 m
2
3G x 1,5 mm
3G x 2,5 mm
2
4G x 1,5 mm
4G x 1,5 mm
2
2 x 1,5 mm
2 x 1,5 mm
2
2 x 0,5 mm
2 x 0.5 mm
2
4 x 0,5 mm
4 x 0,5 mm
2
2 x 0,5 mm
2 x 0,5 mm
2
2 x 0,5 mm
2 x 0,5 mm
max. 10 m
1
8
Length of cable
20 < 30 m
2
2
3G x 4 mm
2
2
4G x 2,5 mm
2
2
2 x 1,5 mm
2
2
2 x 0,5 mm
2
2
4 x 0,5 mm
2
2
2 x 1 mm
2
2
2 x 0,5 mm
6
1
8