PROGRAMMING FUNCTIONS
Access the parameter menu by holding the ENTER button until the first parameter, A, appears. Press the
ENTER button repeatedly to advance through the parameters menu. To change the parameter press ↕
UP/DOWN
FUNCTIONS \ VALUES
WORKING
TIME
A
(seconds)
DOOR2
DELAY
TIME
B
(seconds)
AUTOMATIC
CLOSURE
C
(seconds)
OPEN COMMAND
D
%DECELERATION
E
ELECTRIC
LOCK
F
HAMMERING
FLASHER OUTPUT
G
CONDOMINIUM
H
(OPENING ONLY)
MOTOR
WARM-UP
I
(minutes)
MOTOR FORCE
L
N° OF MOTORS
M
CLOSE AFTER TRANSIT
O
TIMER/MAGNETIC COIL
P
ON STEP/STEP
SOFT START DELAYED
R
START TIME
MAN PRESENT
U
PRE-FLASHING
Y
N.B.: any variation in function must be made with the automation closed
Upon termination of displaying of parameters, you will access the total manoeuvres counter, which are
shown in two different screens where the thousands are indicated by the point lighting up. If you want to rest
this counter, press and hold button P1 and P2 until 0000 is shown
N.B. If the point of the LCD on the left lights up, it means that 10,000 manoeuvres have been exceeded,
which must be added to the value shown.
To exit parameter display, press ENTER several times until automatic closure condition is shown ( -- two
dashes).
0
1
2
--
13
16
--
0
1
NO
5
10
Open
Open
By activating the step/step function, you avoid passage of the automation
Stop
Close
in the stop state. The enabled function may be critical for automations with
close
high inertia.
NO
10%
20%
NO
YES
If you select the Hammering parameter, the control unit facilitates the
release of the electric lock, ordering the motors to close for a short time
Flashing
Courtesy
With this selection you can select output n°9-10 as flasher or courtesy light
light
NO
YES
Activate the condominium function so that the first step/step impulse
opens and accepts only re-opening during closing
NO
15
25
100%
10%
20%
Max
Min
2
1
Parameter of selection of automation with 1 or 2 motors
NO
YES
When you activate the Close After Transit function with automatic closure
activated, the automation is closed in the shortest time possible without
waiting for automatic re-closing.
NO
YES
When you activate the function Timer / Magnetic Coil via parameter P
after terminating total opening if step/step contact N.8 is kept closed the
automatic closing time is locked so that the gate never closes until the
step/step contact is opened again, if there are several step/step impulses
during the standby time for automatic closing the time will be continuously
reset
NO
YES
When you activate the Soft Start function, during the first seconds of
movement of the automation the control unit keeps the motor at reduced
speed for a softer start.
NO
YES
When you activate the Man Present function via parameter U, you can
open the automation until step/step contact N.8 is closed and close the
automation until contact PED n.7 is closed; when the two contacts are
released the automation goes to STOP position.
NO
1sec
2sec
17
3
4
5
6
19
22
25
30
4
10
With this selection you can delay start-up of the
second motor M2 by the set time
15
20
25
30
30%
When the deceleration function is activated in the last
seconds of operation of the automation, the control unit
slows the motors based on the selected %.
40
If you insert parameter I = from 1 to 3 and if the gate is
standing closed in standby at the end of the set time
there will be a closure of both doors of 1 min. at a value
of power that does not damage the motor or the
mechanics. This makes it possible to keep the internal
temperature of the electric motor at a point where ice
does not form in the mechanical reduction gear. This
function should be used when temperatures of less than
5°C are expected.
30%
40%
50%
60%
4sec
When the pre-flashing function is activated, before any
movement the flasher is activated for the selected time
7
8
9
10
35
80
40
80
120
70%
80%
90%
GB