Inhaltszusammenfassung für Daikin VRVIII-Q Serie

  • Seite 1 OPERATION MANUAL System air conditioner Series English Deutsch Français Español Italiano ΕλληνικÜ Nederlands MODELS RQYQ8PY1B RQYQ30PY1B RQYQ10PY1B RQYQ32PY1B Portugues RQYQ12PY1B RQYQ34PY1B RQYQ14PY1B RQYQ36PY1B RQYQ16PY1B RQYQ38PY1B Рóссêий RQYQ18PY1B RQYQ40PY1B RQYQ20PY1B RQYQ42PY1B RQYQ22PY1B RQYQ44PY1B RQYQ24PY1B RQYQ46PY1B Türkçe RQYQ26PY1B RQYQ48PY1B RQYQ28PY1B...
  • Seite 3 Wir möchten uns bei Ihnen dafür bedanken, daß Sie sich für ein Klim- agerät von Daikin entschieden haben. Lesen Sie sich diese Bedienung- Hartelijk dank voor uw keuze van een Daikin airconditioner. Lees deze sanweisung sorgfältig durch, bevor Sie das Klimagerät in Betrieb gebruiksaanwijzing zorgvuldig door voordat u de airconditioner in gebruik nehmen.
  • Seite 5 ouble-flow Multi-flow Corner Ceiling Suspended Wall Mounted...
  • Seite 7: Inhaltsverzeichnis

    RQYQ8PY1B RQYQ18PY1B RQYQ28PY1B RQYQ38PY1B RQYQ48PY1B Operation RQYQ10PY1B RQYQ20PY1B RQYQ30PY1B RQYQ40PY1B VRVIII-Q System RQYQ12PY1B RQYQ22PY1B RQYQ32PY1B RQYQ42PY1B air conditioner manual RQYQ14PY1B RQYQ24PY1B RQYQ34PY1B RQYQ44PY1B RQYQ16PY1B RQYQ26PY1B RQYQ36PY1B RQYQ46PY1B CONTENTS CAUTION ..Failure to observe these instructions properly may result 1. SAFETY PRECAUTIONS ....... 1 in property damage or personal 2.
  • Seite 8 Consult your local dealer regarding what to Do not use flammable materials (e.g., hairspray do in case of refrigerant leakage. or insecticide) near the product. When the air conditioner is to be installed in a Do not clean the product with organic sol- small room, it is necessary to take proper mea- vents such as paint thinner.
  • Seite 9 Do not allow a child to mount on the outdoor Do not place water containers (flower vases, unit or avoid placing any object on it. etc.) on the unit, as this may result in electric Falling or tumbling may result in injury. shocks or fire.
  • Seite 10: Specifications

    Before initiating operation, 10. Display “ ” (under centralized control) contact your Daikin dealer for the operation that cor- When this display shows, the system is under responds to your system type and mark. centralized control. (This is not a standard spec- If your installation has a customized control system, ification.)
  • Seite 11: Operation Range

    16. Inspection/test operation button 5. OPERATION RANGE This button is only used by qualified service Use the system in the following temperature and persons for maintenance purposes. humidity ranges for safe and effective operation. 17. Programming time button COOLING HEATING Use this button for setting the programming start outdoor temperature –5°~43°CDB...
  • Seite 12: Program Dry Operation

    FOR SYSTEMS WITHOUT COOL/HEAT SELEC- EXPLANATION OF HEATING OPERATION TOR (Refer to figure 4) • For general heating operation, it may take longer to reach the set temperature than in cooling operation. Press the operation mode selector button sev- We recommend starting the operation which was eral times and select the operation mode of used before using timer operation.
  • Seite 13: Adjusting The Air Flow Direction

    • The movable limit of the flap is changeable. Press the air flow direction adjust button (only Contact your Daikin dealer for details. (only for FXC, FXF, FXK, FXH, FXA). Refer to the for FXC, FXF, FXK, FXH, FXA) chapter “Adjusting the air flow direction”...
  • Seite 14: Optimum Operation

    When the timer is programmed to stop the sys- NOTE tem after 3 hours and start the system after 4 • Contact your Daikin dealer in case of chang- hours, the system will stop after 3 hours and ing the combination or setting of group con- start 1 hour later.
  • Seite 15: Seasonal Maintenance

    • Turn off the main power supply switch to the unit 8-2 AT THE END OF THE SEASON when the unit is not used for longer periods of On a clear day, use fan operation for around half a time. If the switch is on, it uses electricity. Before day to thoroughly dry out the interior of the unit.
  • Seite 16 9-9 DUST COMES OUT OF THE UNIT room becomes uneven. It is necessary to clean the interior of the indoor unit. Ask your Daikin • When the unit is used after stopping for a long dealer for details on cleaning the unit. This opera- time.
  • Seite 17: Trouble Shooting

    3. Operation lamp ing the compressor so that the compressor 4. Malfunction code can start smoothly. Measure: Notify your Daikin dealer and report the malfunction code. 9-15 IT STOPS SOMETIMES If the system does not properly operate except • The remote controller display reads “U4” and for the above mentioned cases and none of the “U5”...
  • Seite 18: After-Sales Service And Warranty

    2. If the system stops soon after starting the opera- • Do not remove or reinstall the unit by yourself. tion; Incorrect installation may cause electrical shock • Check if air inlet or outlet of outdoor or indoor unit or fire. is not blocked by obstacles.
  • Seite 19: Warranty Period

    ■ Recommended replacement cycle of wear-out • Table 1 “Inspection Cycle” and “Maintenance Cycle” Lists parts Maintenance Cycle [The cycle is not the same as the warranty period.] Inspection Name of Main Part [replacements and/ Cycle • Table 2 “Replacement Cycle” Lists or repairs] Electric motor (fan, Inspection...
  • Seite 20 3P226891-12Q EM10A039 (1012) HT...

Inhaltsverzeichnis