4.4) ERRORS:
these appear during operation, combined with a beep and flashing LED Worklights,
to notify the operator of procedural or operational errors.
Message
Error description
The pressure release button (5) was
pressed before the control parameters
ERROR
were reached (Force/Pressure).
Interruption of the signal from the
NTC
ERROR
NTC temperature probe of the battery.
FAULT
001
ERROR
ERROR
Abnormal power consumption of the
ERROR
002
motor for more than 3 seconds.
001
The tool stops.
001
003
001
002
Output voltage of the pressure trans-
001
002
mitter is out of the pre-set range.
004
002
003
002
Failure to reach the set pressure within
003
003
30 seconds of continuous operation
004
of the machine.
003
004
Overcharging of the battery with
004
protection tripping.
004
The tool stops.
Errors are displayed for about 30 seconds before being reset, but will display repeatedly in
the event of permanent anomalies.
5. CONNECTION TO COMPUTER (Smartool thecnology)
The memory card integrated in the tool records operating datafor transfer via the USB cable supplied.
To view and manage this data, go to www.cembre.com and register in the dedicated area, then
download the free Cembre software CEM_SWBT01.
Keeping the Firmware of the tool updated, via free of charge download from here, will optimise
the tool's performance.
6. RETURN TO Cembre FOR OVERHAUL
In the case of a breakdown contact our Area Agent who will advise you on the problem and give
you the necessary instructions on how to dispatch the tool to our nearest service Centre; if possible,
attach a copy of the Test Certificate supplied by Cembre together with the tool or fill in and attach
the form available in the "ASSISTANCE" section of the Cembre website.
Solution
Repeat the work cycle and wait for the
motor to stop automatically.
Replace the battery.
If the problem persists, please contact
Cembre.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery,
then re-start the tool.
If the error occurs frequently, contact
Cembre.
Repeat the work cycle; if the error
occurs frequently, contact Cembre.
Repeat the work cycle; if the error
occurs frequently, contact Cembre.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery,
then re-start the tool.
If the error occurs frequently, contact
Cembre.
12