2. Open the terminal box at the rear side of the
heater and connect the power supply cable
in accordance with the connection diagram
(see chaper Electrical Connection) as per po-
wer supply type. The default connection dia-
gram is also attached inside terminal box of
the heater.
ATTENTION: Make sure to observe the con-
nection diagram. Pay attention to the correct
power supply.
Cable gland
Terminal block
wall-mounting bracket
28
Terminal box cover
with spacer
Fig. 4
Lock nut
Illust. 5
Fig. 6
3. Close the terminal box with cover using 2
fixation screws. Observe that the integrated
spacer faces outwards. See Illust. 4 for details.
4. Hook the sauna heater into the wall moun-
ting using the mounting slots on the rear
wall. Make sure that the heater securely
hangs on the mounting bracket and the
spacer at the terminal box has a full contact
to the sauna wall. See Illust. 6. Observe that
the 18 cm floor gap is maintained.
5. Fasten the sauna heater to the wall mounting
through the hole located on the rear edge of
the oven using self-tapping screw (Illust. 7).
Securing screw
Sicherungsschraube
Attention! Make sure to provide an air intake
vent below beneath the sauna heater. The air
intake vent and the exhaust air vent should
have the appropriate size as per heater power:
4.5 kW
6.0 kW
7.5 kW
9.0 kW
Make sure there is a stable fresh air supply
through the air intake vent.
The lack of the sufficient fresh air supply may
cause overheating and lead to damages of
the sauna heater. The warranty will be void in
such case.
EN
Fig. 7
Abb. 7
35 x 3 cm
35 x 4 cm
35 x 5 cm
35 x 6 cm