2.7. Safety and control devices

Our products are equipped with various safety and con-
trol devices. These include, for example suction strainers,
thermo sensors, sealed room monitor etc. These devices
must never be dismantled or disabled. Equipment such as
thermo sensors, float switches, etc. must be checked by
an electrician for proper functioning before start-up (see
the "Electrical Connection" data sheet). Please remember
that certain equipment requires a decoder device or relay
to function properly, e.g. posistor and PT100 sensor. This
decoder can be obtained from the manufacturer or a spe-
cialist electronics dealer.
Personnel must be informed of the installations used and
how they work.
Caution!
Never operate the machine if the safety and monitor-
ing devices have been removed or damage, or if they
do not work.

2.8. Operation in an explosive atmosphere

Products marked as explosion-proof are suitable for opera-
tion in an explosive atmosphere. The products must meet
certain guidelines for this type of use. Certain rules of con-
duct and guidelines must be adhered to by the operator
as well. Products that have been approved for operation
in an explosive atmosphere are marked as explosion-pro-
tected "Ex" . In addition, an "Ex" symbol must be included
on the type plate! When used in an explosive atmosphere,
the additional chapter entitled "Explosion protection
according to the ...standard" must be observed!

2.9. Sound pressure

Depending on the size and capacity (kW), the products
produce a sound pressure of approximately 60 dB (A) and
110 dB (A). The actual sound pressure, however, depends
on several factors. These include, for example, the instal-
lation type (wet, dry, transportable), fastening of accesso-
ries (e.g. suspension unit) and pipeline, operating site, im-
mersion depth, etc. Once the product has been installed,
we recommend that the operator make additional mea-
surements under all operating conditions.
Caution: Wear ear protectors!
In accordance with the laws in effect, guidelines,
standards and regulations, ear protection must be
worn if the sound pressure is greater than 85 dB (A)!
The operator is responsible for ensuring that this is
observed!

2.10. Pumped fluids

Each pumped fluid differs in regard to composition, cor-
rosiveness, abrasiveness, TS content and many other
aspects. Generally, our products can be used for many
applications. For more precise details, see chapter 3, the
machine data sheet and the order confirmation. It should
be remembered that if the density, viscosity or the general
composition change, this can also alter many parameters
of the product. Different materials and impeller shapes
are required for different pumped fluids. The more exact
your specifications on your order, the more exactly we can
modify our product to meet your requirements.
If the area of application and/or the pumped fluid change,
we will be happy to offer supportive advice.
When switching the product into another pumped fluid,
observe the following points:
Products which have been operated in sewage or
waste water must be thoroughly cleaned with pure
water or drinking water before use.
Products which have pumped fluids which are haz-
ardous to health must always be decontaminated be-
fore changing to a new fluid. Also clarify whether the
product may be used in a different pumped fluid.
With products which have been operated with a
lubricant or cooling fluid (such as oil), this can escape
into the pumped fluid if the mechanical shaft seal is
defective.
Danger - explosive fluids!
It is absolutely prohibited to pump explosive liquids
(e.g. gasoline, kerosene, etc.). The products are not
designed for these liquids!

3. General description

3.1. Application

Wastewater disposal with small pipe cross-sections, large
delivery heads at relatively low flow rates, pressure drain-
age systems in topographically difficult areas.
The pumps are not suitable for pumping media with highly
abrasive components (e.g. sand, gravel, stone).
In the case of chemically aggressive components in the
pumped medium, it is essential to consider the resistance
of the materials used. For this purpose, the aggregates
can be supplied partially or made of highly resistant mate-
rials (stainless steel).
Use in slurping operation is not permitted. The min-
imum level of the pumped medium must always be
above the upper edge of the pump housing. For wet
installation without cooling jacket, the motor housing
must always be completely submerged.
The temperature of the conveyed medium may be up to
40 °C, or up to 60 °C for a short period. The maximum den-
sity of the medium is 1040 kg/m³ and the pH may be from
6 – 11. However, the pH alone only serves as a guideline.
In any case, alongside the composition of the medium,
the durability of the pump must be requested from the
manufacturer. Depending on the composition, it may be
necessary to use special sealing materials.

3.2. Types of use

The motors are designed for continuous operation (S1),
maximum 15 starts per hour.
The hydraulic is designed for permanent operation, e.g.
supply of industrial water.