13. Technical Data

The Elvas, certifi ed in compliance with DIN-EN 13240 and Art. 15 a B-VG (Austria),
can only be operated when the fi re box is closed. Conforms with the DIBt (Deutschen
Institut für Bautechnik/German Institute for Building Technology) approval criteria for
direct vent fi replaces for solid fuels. Multiple connections to the chimney are pos-
sible, see point 4. "Connection of Multiple Devices in Direct Vent Operation".
DIBt approval number: Z-requested / Typ FC61x
The following data applies to the chimney characteristics in accordance with
EN 13384-1 / 2:
Combustion Values*
Nominal Thermal Output
Room heating output
Exhaust gas temperature
Waste Gas Outlet Temp.
Waste Gas Mass Flow Rate
Min. Supply Pressure at Nominal Thermal Output**
Effi ciency
CO content
Particulate
OGC
NO
X
Min. required combustion air volume
*
Test bench performance and values at 13% O
**
The additional supply pressure required for the combustion air connection with the Hase Air System:
below= 2 Pa, behind= 3 Pa
Depending on the insulation of the building, the nominal thermal output of 5 kW indi-
cated on 15 - 60 m² (subject to change).
Dimensions:
Height
Stove
142 cm
Fire box
42 cm
42
All manuals and user guides at all-guides.com
Wood
5
kW
5,5
kW
225
˚C
270
˚C
5,5
g/s
Pa
12
81
%
1250
mg/Nm³
19
mg/Nm³
111
mg/Nm³
160
mg/Nm³
21
m³/h
2
Width
39 cm
20 cm
Weight
¹Vertical fl ue pipe length
Flue pipe diameter
Pipe diameter of Hase ventilation system***
Front view Elvas:
39
Top view Elvas:
Depth
39 cm
***
For separate air supply in low-energy houses and insuffi cient combustion air supply in the room
23 cm
where the stove is installed.
152 kg
min. 33 cm
15 cm
10 cm
Side view Elvas:
10
Inst. of Hase air system
below
Dimensions in cm