INSTALLATION INSTRUCTIONS
right-hand zones
left-hand zones
right-hand zones
left-hand zones
right-hand zones
left-hand zones
right-hand zones
left-hand zones
Common connection:
3 phase with 1 zero connection (3 1N a.c. 400V / 50 Hz):
appliance
interior
The voltage between the phases and the zero is 230 V a.c. The
voltage between the two phases is 400 V. Fit a connecting bridge
between connecting pointsmiddle zones left-hand zones 1 - 2 and
4 - 5. Phase 3 is not used. The groups must have fuses of at least
16 A (3x). The core diameter of the connecting cable must be at
least 2.5 mm2.
2 phase and 2 zero connection (2 2N a.c. 230V / 50 Hz):
appliance
interior
The voltage between the phases and the zero is 230 V a.c.
The group must have fuses of at least 16 A (2x). The core diame-
ter of the connecting cable must be at least 2.5 mm2.
Special connections:
appliance
interior
Single phase connection (1 1N a.c. 230V / 50 Hz):
The voltage between the phase and the zero is 230 V a.c.
The group must have a fuse of at least 32 A. The
core diameter of the connecting should be at least 6 mm2.
3 phase, no zero connection (3 a.c. 230V/50 Hz):
The voltage between the phases is 230V a.c.
appliance
interior
Fit connecting bridges between connecting points
4 and 5. The group must have fuses of at least 16 A (3x). The
corediameter of the connecting cable must be at least 2.5 mm2.
E E l l e e c c t t r r i i c c a a l l c c o o n n n n e e c c t t i i o o n n
The bridges on the connecting block can be used to create the
required connections, as indicated in the illustrations on the
previous page.
Fix the cable with a pull relief and close the cover. Ensure the con-
necting point remains easily accessible.
electrical connection
20