Spezifikationen
Endung ".0" und spezifizieren nur einen Wert. Bei SNMP Tabellen wird das "x" durch
einen Index (1 oder größer) ersetzt, um einen Wert aus der Tabelle zu adressieren.
Name
enc2111TrapCtrl
enc2111TrapIPIndex
enc2111TrapAddr
enc2111portNumber
enc2111PortIndex
enc2111PortName
enc2111PortState
enc2111PortSw itchCount
enc2111PortStartupMode
enc2111PortStartupDelay
enc2111PortRepow erTime
epc2111PortResetDuration
enc2111ActiveInputs
enc2111InputIndex
enc2111Input
enc2111InputName
enc2111State12V
enc2111State3V
enc2111POE
enc2111Pw rSupplyIndex
enc2111Pw rSupplyStatus
epc2111NTPTimeValid
epc2111NTPUnixTime
epc2111NTPLastValidTimestamp
enc2111SensorIndex
enc2111TempSensor
enc2111HygroSensor
enc2111InputSensor
83
Expert Net Control 2111/2191
OID
Description
.60.1.1.1.1.0
0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3
.60.1.1.1.2.1.1.x
A unique value, greater than zero, for each receiver slot.
.60.1.1.1.2.1.2.x
DNS name or IP address specifying one Trap receiver slot. A port can
optionally be specified: 'name:port' An empty string disables this slot.
.60.1.3.1.1.0
The number of Relay Ports
.60.1.3.1.2.1.1.x
A unique value, greater than zero, for each Relay Port.
.60.1.3.1.2.1.2.x
A textual string containing name of a Relay Port.
.60.1.3.1.2.1.3.x
current state of a Relay Port
.60.1.3.1.2.1.4.x
The total number of sw itch actions ocurred on a Relay Port. Does not
count sw itch commands w hich w ill not sw itch the ralay state, so just
real relay sw itches are displayed here.
.60.1.3.1.2.1.5.x
set Mode of startup sequence (off, on , remember last state)
.60.1.3.1.2.1.6.x
Delay in sec for startup action
.60.1.3.1.2.1.7.x
Delay in sec for repow er port after sw itching off
.60.1.3.1.2.1.8.x
Delay in sec for turning Port on again after Reset action
.60.1.5.6.1.0
Number of suppported Input Channels.
.60.1.5.6.2.1.1.x
None
.60.1.5.6.2.1.2.x
Input state of device
.60.1.5.6.2.1.32.x
A textual string containing name of the Input
.60.1.5.7.1.0
Show state of internal 12V
.60.1.5.7.2.0
Show state of internal 3.3V
.60.1.5.10.0
signals POE availability
.60.1.5.13.1.1.x
Index of Pow er Supply entries
.60.1.5.13.1.2.x
show s status of the Pow er Supply 1 = fst, 2 = snd etc.
.60.1.5.15.1.0
Show if valid Time is received
.60.1.5.15.2.0
show received NTP time as unixtime (secs since 1 January 1970)
.60.1.5.15.3.0
show seconds since last valid NTP timestamp received
.60.1.6.1.1.1.x
None
.60.1.6.1.1.2.x
actual temperature
.60.1.6.1.1.3.x
actual humidity
.60.1.6.1.1.4.x
Type
Acc.
Integer32
RW
Integer32
RO
OCTETS
RW
Integer32
RO
Integer32
RO
OCTETS
RW
INTEGER
RW
Integer32
RO
INTEGER
RW
Integer32
RW
Integer32
RW
Integer32
RW
Unsigned32
RO
Integer32
RO
INTEGER
RO
OCTETS
RW
INTEGER
RO
INTEGER
RO
INTEGER
RO
Integer32
RO
INTEGER
RO
INTEGER
RO
Unsigned32
RO
Unsigned32
RO
Integer32
RO
Integer32
RO
Integer32
RO
INTEGER
RO
© 2022 GUDE Systems GmbH