Installation

4.2 Electrical installation

Destruction of parts of equipment and loss of regulation control
WARNING
` All lines for connecting the encoder must be shielded.
` Never wire or disconnect electrical connections while they are live.
` Perform wiring work in the de-energized state only.
` Use strands with suitable ferrules.
` Check all lines and plug connections before switching on the device.
` Switch on operating voltage together with the downstream electronic
Basically, all connections are protected against external interference.
NOTICE
Choose a place of operation that excludes inductive or capacitive interfer-
ence influences on the encoder. When mounting the system keep a maxi-
mum possible distance from lines loaded with interference. If necessary,
provide additional installations including screening shields or metallized
housings. Contactor coils must be linked with spark suppression.
The cable shield is internally connected to the encoder housing. When
NOTICE
connecting via a stator coupling, make sure that it is sufficiently conduc-
tive. Otherwise, the housing should be connected directly to a protective
ground.
Admissible power input
Supply for the encoder shall be sized sufficiently. The voltage values are a
NOTICE
function of the device design and can be referred to in the technical data
in chapter 8.
Connection type
• E1: open cable end.
Color
green
brown
white
pink
grey
AH3650M, AV3650M · Date 07.03.2022 · Art. No. 90765 · Mod. status 46/22
unit (e. g., control unit).
Designation
Iout/Uout
+UB
GND
Limit 2
Limit 1