Electrical installation
6.6
Minimum bending radius for the brake connection line
Size
06
08
10
12
14
16
18
20
25
Tab. 13: Minimum bending radius for the brake connection cable
6.7
Technical specifications for the micro-switch
The brake can be equipped with a micro-switch for monitoring the release or wear. The micro-switch can
be integrated into the circuit as an NO or NC contact.
As of June 2012, a new small micro-switch (with UL acceptance) is in use, which is perfectly adapted to
the contour of the brake. The old switch design can be converted by connecting an adapter to the same
threaded holes.
Design
3-pole connecting cable
Contacts
Current carrying capacity 250 V AC
Current carrying capacity 30 V DC
Minimum load at 24 V DC
Temperature range:
Protection class
Tab. 14: Technical specifications for the micro-switch
BK
1
Tab. 15: Switching states of the mechanical micro-switches
INTORQ | BA 14.0168 | 08/2019
Wire cross-section
Switching states
BN
Check of air gap
2
BU
4
Monitoring wear
AWG 20
Micro-switch
3 x 0.34 mm² (AWG22)
black / brown / blue
D = 4.8 mm, black, CSA
Style 2517/105°
Length: 1000 mm
Silver
Max. 3 A
Max. 3 A
10 mA
-40 °C to +85 °C
IP67
s
= 0
L
1 - 4
1 - 4
Minimum bending radius
27.5 mm
45.6 mm
s
s
(-0.1)
LN
Lmax
1 - 2
1 - 2
1 - 4
1 - 2
54