Herunterladen Diese Seite drucken
Vorschau ausblenden Andere Handbücher für Talis S2 32440000:

Werbung

Important! The fitting must be installed, flushed and
tested after the valid norms!
Assembly
1.
Flush through the supply pipes.
2.
Mount the S - unions and align them.
3.
Fasten the mixer with the washers.
The hot and cold supplies must be of equal
pressures.

Operation

The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
32420000: The flow is changed from bath to shower
function by pulling the knob at the upper side of the
spout. After shutting off the water flow, the mixer
returns automatically to the bath function.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G ½":
Rate of flow:
Test certificate
DVGW
32440000
32640000
32643000
anti-pollution function
All manuals and user guides at all-guides.com
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80° C
65° C
cold right - hot left
ca. 22 l/min 0,3 MPa
P-IX
SVGW
PA-IX
X
18311/ICB
PA-IX
X
18310/IB
X
English
To adjust the hot water limiter on single lever
mixers, please see page 7.
No
adjustment
continuous flow water heater.
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
Important!
The non return valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once a
year).
Spare parts (see page 4)
1
handle
1.1 screw cover
2
flange
3
nut
4
cartridge cpl.
5
flange 32440000/32640000
6
S-union 32440000/32640000
7
aerator cpl.
8
selector assy
9
diverter knob
10
non return valve
ACS
is
necessary
when
NF
WRAS
using
a
32096000
96338000
97406000
97209000
92730000
96467000
94140000
13914000
97978000
96466000
94074000
KIWA
5