Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The product may only be used for bathing, hygienic and body cleaning
purposes.
Children may only use the product unsupervised if they have been suitable
instructed and trained to use the product safely and to understand the risks of
improper operation.
Only the battery housing with battery CR-P2 or power pack HG No.
30589310 supplied by Hansgrohe may be connected to the electrical
connection cable of the fittings.
A damaged connecting line must not be replaced. The transformer may no
longer be used.
The transformer and its mains plug may only be installed or plugged in in dry
interior rooms outside of the protected zones.
The transformer must not be installed in protection zones 0 or 1.
The wall socket must be outside of the protected zones. (see page 7, Fig. 8)
The fitting may be installed in protected zone 2.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
Leave enough space above the tap for servicing. (min. 200 mm)Special informa-
tion for UK If installing this product with a pump, please be aware that it has to
have negative head switching. This product will not function with a positive head
pump.
• 71501009, 71502009: The mixer can not used together with a continuous
flow water heater.
Electrical installation
Electrician
The installation and test work must be performed by an authorized electrician
under consideration of DIN VDE 0100 part 701 / IEC 60364-7-701.
Electrical connection
Voltage supply: 230 V AC ± 10 %/ 50- 60 Hz
The circuit must be protected via a ground fault protector (RCD / FI) with a
measured differential current of ≤ 30 mA. The proper function of this protective
device must be checked at regular intervals.
Any work may only be carried out in a de-energized state. Here, the voltage
supply must be safely separated via the main switch or mains plugs.
The wall socket must be outside of the protected zones. (see page 7, Fig. 8)
Adjustment
This mixer has the following feature: background fade-out with integrated range
adjustment, that means the mixer is automatically adjusted on to the local
conditions (washbasin, brightness, reflection) by the sensory mechanism.
Battery operation
The indicator LED signals that the battery must be changed. (see page 10).
Attention! After insertion of the battery, the fitting should not be activated for
approx. 35 seconds. This time is required for self-adjustment.
Power supply pack operation
For the replacement of a power supply pack, the procedure corresponds to the
replacement of a battery.
Normal operation
The range of the detection area or the removal of the switch-on/off point from the
fittings depends on the ambient optical conditions (for example, the shape and
reflection of the washstand and the ambient light) as well as on the shape, the size,
the speed and the reflection of the object that was brought into the detection area.
The detection area of the fittings or the distance of the switch-on/off point from the
fittings is approx. 160 to 200 mm in normal operation. The detection of dark (for
example grey-black) objects by the fittings is inadequate because of their low
reflection. The range of the detection area or the distance of the switch-on/off
point can be smaller than 160 mm. The detection of bright or reflecting objects by
the fittings is very good as a result of their high reflectivity. The range of the
detection area or the distance of the switch-on/off point can be greater than
200 mm. Strong light sources should not shine directly on the sensor window of the
2
English
fittings. Drops of water or condensed water on the sensor window of the fittings
can initiate unintended running of the water.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Maximum flowing-out temperature at 50 K temperature difference and 0,3 MPa
flow pressure:
Follow-up time:
Automatic switching-off:
battery:
transformer:
Protection category:
installation site of type plate:
The product is exclusively designed for drinking water!
max. 0,8 MPa
0,1 - 0,5 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
max. 34°C
10 s / 20 s / 30 s / 60 s (Factory preset)
CR-P2 / 6 V Lithium
230 V AC ± 10 % / 50 – 60 Hz / 30 mA
see page 14
1,6 MPa
1 - 2 s
IPX9