Operation
GB
GB
Switching the radiator on/off
The thermostat has four keys and a display.
The On/Standby 14 key is used to switch the thermostat
on or switch it to standby. When the thermostat is switched
to standby, a flashing dot appears on the display. When the
thermostat is on, the display shows the time and program,
the weekly program mode or the temperature setting (in
the other modes). When switching from standby to on, the
buzzer is activated and a beep sounds, which lasts approx.
1 second. When switching from on to standby, the buzzer
is also activated and two short beeps sound at an interval of
approx. 0.5 seconds.
Stand-by function
Only a flashing dot is shown on the display.
There is no temperature control and the electric heating
element is switched off. When pressing the key On/Standby
14, the thermostat is switched on.
Description of functions
The thermostat has different operating modes:
weekly program, sensor, comfort, night and antifreeze
To switch to the current operating mode, press Function
key 13.
High temperature = TH - key 12 (-)
Low temperature = TL - key 11 (+)
Setting the current time
To change the time, press Function key 13 for longer than
2 seconds until the time display starts to flash. To set the
current hour, use Key 12 (-) or Key 11(+). To change to the
minute display, press Function key 13. To set the current
minute, use Key 12 (-) or Key 11(+). To confirm, press Func-
tion key 13 again.
Setting the modes
Comfort mode
You can adjust the required room temperature with this
mode. The display shows the sun symbol and the tempera-
ture TH. To change the temperature setting, press and hold
Key 12 (-) or Key 11 (+) and select the required value. The
room temperature is regulated by setting TH.
Night-time mode
You can adjust the required lowered temperature with this
mode. The display shows the moon symbol and the temper-
ature TL. To change the temperature setting, press and hold
Key12 (-) or Key 11 (+) and select the required value. The
room temperature is controlled by setting TL.
Antifreeze mode
The snowflake symbol appears on the display and the room
temperature is constantly adjusted to the freezing threshold
of 7°C.
Automatic mode (temperature sensor)
In automatic mode, the high temperature (set locally in
comfort mode) is changed by the commands received from
the sensor input, unless the sensor is not connected or in
the case of class I devices (devices with earth connection).
The display shows the house symbol and the symbol ob-
tained via the sensor command: only for Comfort command
or no command.