Number
Designation
Enclosed accessories
–
Grommet
–
3/8 flexible connection pipe (for pres-
sure-tight system) (VED E 11-13/1 L F
only)
–
3/8 T connecting element (for pressure-
1
tight system) (VED E 11-13/1 L F only)
–
Seals (for pressure-tight system)
–
Filter (at the product's cold water con-
nection)
–
Wall plug
–
Screws
4.2
Minimum clearances
Validity: Pressure-tight installation with high-pressure water tap
≥20
Validity: Non-pressurised installation with low-pressure water tap
≥20
38
≥20
≥20
4.3
Product dimensions
100
140
174
4.4
Requirements for the installation site
▶
Select the installation site so that the pipes can be easily
routed (water supply and drain).
▶
Do not install the product close to stairways or emer-
gency exits.
▶
Always install the product in an upright position.
▶
Install the product in a frost-free room.
▶
Install the product as close as possible to the draw-off
point.
Note
It is not necessary to install an expansion relief
valve.
▶
When installing the product, ensure that the fixing ele-
ments and the wall have sufficient load-bearing capacity.
4.5
Wall-mounting the product
1.
Check the load-bearing capacity of the wall.
2.
Note the total weight of the product.
3.
Only use fixing material that is permitted for the wall.
4.
If required, ensure that mounting apparatus on-site has
sufficient load-bearing capacity.
5.
Wall-mount the product as described.
Installation and maintenance instructions 0020323586_00
101
87
35