BTL7-A/E501-M_ _ _ _-J-DEXC-TA12
Magnetostrictive Linear Position Sensor – Rod Style
12
Accessories
Accessories are not included in the scope of delivery and
must be ordered separately.
12.1
Floats
Only the floats listed here may be used as magnets for
measuring the level in zone 0.
BTL2-S-6216-8P-EX
Order code
BAM014E
Weight
69 g
Housing material
Pressure rating
Up to 15 bar
Ambient
temperature
Minimum density
0.6 g/cm
Immersion depth
Density = 1 g/cm
(H
O)
~41 mm
3
2
Density = 0.7 g/cm
~57 mm
3
Installation position Cylindrical part is the
top side of the float
Spacer
The spacer is included in the scope of delivery of the
following floats:
–
BTL2-S-4414-4Z-EX
–
BTL2-S-4414-4Z01-EX
–
BTL2-S-5113-4K-EX
BTL2-S-6216-8P-EX does not require a spacer.
28
english
BTL2-S-5113-4K-EX
BAM014A
34 g
Up to 40 bar
0.7 g/cm
3
3
~26 mm
~40 mm
Raised marking on the
top side of the float
Type of protection "db" and "t"
BTL2-S-4414-4Z-EX
BAM0147
34 g
Stainless steel
Up to 20 bar
–20°C...+120°C
0.7 g/cm
3
~30 mm
~39 mm
Raised marking on the
top side of the float
Flameproof enclosure
BTL2-S-4414-4Z01-EX
BAM0148
52 g
Up to 20 bar
0.85 g/cm
3
(= float density)
~45 mm
Immersed
Two raised markings
on the top side of the