Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Cleaning, Maintenance And Ordering Of Spare Parts - EINHELL GE-SP 18 LL Li Originalbetriebsanleitung

Akku-klarwasserpumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
All 3 LEDs are lit:
The battery is fully charged.
2 or 1 LED(s) are lit:
The battery has an adequate remaining charge.
1 LED fl ashes:
The battery is empty, recharge the battery.
All LEDs blink:
The battery temperature is too low. Remove the
battery from the equipment, keep it at room tem-
perature for one day. If the fault reoccurs, this me-
ans that the rechargeable battery has undergone
exhaustive discharge and is defective. Remove
the battery from the equipment. Never use or
charge a defective battery.

6. Operation

You can put the equipment into operation after
you have thoroughly read the installation and ope-
rating instructions. Pay attention to the following
points:
Make sure that the equipment is set up se-
curely.
Check that the discharge line is fitted cor-
rectly.
Lower the pump into the well or shaft using a
securing cable, or hang it inside the rainwater
barrel.
The pump will start automatically after you
have pressed the selector switch (7) in the
corresponding pump mode.
Take care that the pump does not run dry.
To switch off the pump, press the pump mode
selector switch so that it is in "0" position.
Switching on the pump
The pump has a pump mode selector switch (7)
on the battery box (6).
Mode "I": Dry-run safeguard
Set the pump mode selector switch (7) to "I". The
pump has a dry-run safeguard when pump mode
is activated. The pump will be switched off auto-
matically if no liquid medium is detected for lon-
ger than 20 seconds. The dry-run safeguard has
tripped. The pump will make no further priming
attempts. Set the pump mode selector switch to
"0" in order to reset the pump.
Anl_GE_SP_18_LL_Li_SPK13.indb 19
Anl_GE_SP_18_LL_Li_SPK13.indb 19
GB
Mode "II": No dry-run safeguard
Set the pump mode selector switch (7) to "II".
When the pump is used in shallow suction mode,
the dry-run safeguard might trip if the fl ow rate
is too low. To use the pump without the dry-run
safeguard, select mode "II". This will deactivate
the dry-run safeguard and the pump will run con-
tinuously. – Caution! Take care that the pump
does not run dry; operate the pump only under
supervision.
7. Cleaning, maintenance and
ordering of spare parts
Danger!
Always pull out the battery pack before star-
ting any cleaning work.
For mobile applications, the equipment
should be cleaned with clear water after every
usage.
Use a water jet to remove any lint or fibrous
particles that may have become trapped in
the housing.
Remove sludge from the shaft bottom and
clean the shaft walls every 3 months.
7.1 Cleaning the paddle wheel
If a lot of deposits collect in the housing, the bot-
tom part of the equipment must be dismantled as
follows:
1. Disconnect the intake cage from the housing.
2. Clean the paddle wheel with clear water. Im-
portant! Do not put down or rest the equip-
ment on the paddle wheel!
3. Assemble in reverse order.
7.2 Maintenance
There are no parts inside the equipment which
require additional maintenance.
7.3 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.Einhell-Service.com
- 19 -
27.07.2021 14:55:39
27.07.2021 14:55:39

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ge-sp 18 ll li-solo41.815.6041.815.61

Inhaltsverzeichnis