The battery pack can become a little warm during
the charging. This is normal.
If the battery pack fails to charge, check:
whether there is voltage at the socket outlet
whether there is good contact at the charging
contacts
If the battery pack still fails to charge, send
the charging unit
and the battery pack
to our customer service center.
To ensure that items are properly packaged
and delivered when you send them to us,
please contact our customer service or the
point of sale at which the equipment was
purchased.
When shipping or disposing of batteries and
cordless tools, always ensure that they are
packed individually in plastic bags to prevent
short circuits and fi res.
To ensure that the battery pack provides long ser-
vice, you should take care to recharge it promptly.
You must recharge the battery pack when you
notice that the performance of the device drops.
Never allow the battery pack to become fully di-
scharged. This will cause it to develop a defect.
5.6 Battery capacity indicator (Fig. 8)
Press the button for the battery capacity indicator
(Item A). The battery capacity indicator (Item B)
shows the charge status of the battery using 3
LEDs.
All 3 LEDs are lit:
The battery is fully charged.
2 or 1 LED(s) are lit:
The battery has an adequate remaining charge.
1 LED blinks:
The battery is empty, recharge the battery.
All LEDs fl ash:
The battery pack has undergone exhaustive di-
scharge and is defective. Do not use or charge a
defective battery pack.
Anl_GE_PP_18_RB_Li_SPK9.indb 21
Anl_GE_PP_18_RB_Li_SPK9.indb 21
GB

6. Operation

You can put the equipment into operation after
you have thoroughly read the installation and ope-
rating instructions. Pay attention to the following
points:
Make sure that the equipment is set up se-
curely.
Check that the discharge line is fitted cor-
rectly.
Lower the pump into the well or shaft using a
securing cable or hang it inside the rainwater
barrel.
The device starts automatically after you have
pressed the On/Off switch (7).
Make sure that the equipment does not run
dry.
To switch off the device, please press the ON/
Off switch (7) again.
7. Cleaning, maintenance and
ordering of spare parts
Danger!
Always pull out the battery pack before star-
ting any cleaning work.
For mobile applications, the equipment
should be cleaned with clear water after every
usage.
Use a water jet to remove any lint or fibrous
particles that may have become trapped in
the housing.
Remove sludge from the shaft bottom and
clean the shaft walls every 3 months.
7.1 Cleaning the fi lter (Figs. 9 and 10)
In order to protect the equipment and the impeller
from severe soiling, an additional fi lter has been
installed in the bottom intake cage. Please pro-
ceed as follows when cleaning the fi lter:
1. Open the fi lter cover (A) in the intake cage
(5).
2. Remove the fi lter (B) and wash it out under
running water.
3. Assemble in reverse order.
7.2 Maintenance
There are no parts inside the equipment which
require additional maintenance.