All manuals and user guides at all-guides.com
6
Troubleshooting
6.1
Error messages
Call up the keypad status messages to see the last error message.
Display ( ERROR ) Error
NO ERROR
PR ERROR
COM BROK
RESET ERROR Communicatio
ASIC ERROR
SDO ERROR
L
Troubleshooting and fault elimination
Cause
No error
-
Faulty data
Connection between keypad
exchange
and PC faulty
Communicatio
Serial data cable between
n interrupted
keypad and PC faulty or not
connected properly
•
Incorrect system bus wiring
n with system
n with system
(e.g. pole connection)
(e g pole connection)
•
bus (CAN)
Incorrect parameter setting
p
interrupted
interrupted
for interface (baud rate,
f i t f
address, identifier)
EDBEPM-H510 DE/EN/FR 2.0
( ^ 56)
Remedy
-
•
Check connection
•
Check cable
•
Check Sub D plug connection
•
Replace serial data cable
•
Check wiring ( ^ 51 )
•
•
Check parameter setting ( ^ See
Check parameter setting ( ^ See
g
"HMI Designer - Getting Started"
(b d t
M
Manual )
l )
g
g
67