Every 250 operating hours
•
Replace air intake filter element of
compressor pump.
•
Replace air filter element of filter/
regulator unit.
Every 500 operating hours
•
Pump out oil through dip stick's
plastic pipe and fill in fresh oil.
Pumping can be done with a suita-
ble handpump or by an authorised
service station.
Every 1000 operating hours
•
Have unit serviced by an authorised
service station. This will extent the
compressor's service life considera-
bly.
5.2
Device storage
1.
Switch unit OFF and unplug.
2.
Release pressure from tank and all
connected air tools.
3.
Store device in such way that it can-
not be started by unauthorised per-
sons.
A
Caution!
Do not store device unpro-
tected outdoors or in damp environ-
ment.
Do not lay device on its side for trans-
portation or storing.
6. Trouble shooting
A
Danger!
Prior to all servicing:
− Switch Off.
− Unplug.
− Wait until the device has come to
a complete stop.
− Ensure the device and all air tools
and accessories connected to it
are relieved from pressure.
− Let the device and all air tools
and accessories used cool off.
After all servicing:
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts remain on or in the device.
Compressor does not run:
•
No mains voltage.
− Check cables, plug, outlet and
mains fuse.
•
Mains voltage too low.
− Use only extension cables of suf-
ficient lead cross section (see
"Technical specifications"). Avoid
using
extension
device is cold.
•
Compressor
was
unplugging.
− Switch compressor OFF at the
On/Off switch, then ON again.
•
Motor overheated, e.g. by insuffi-
cient cooling (cooling fins covered).
− Turn compressor OFF at the On/
Off switch. Remove cause for
overheating, let cool off for
approx. 10 minutes, then turn ON
again.
Compressor runs but does not build
up sufficient pressure.
•
Condensate drain of pressure ves-
sel leaky.
− Check gasket of drain cock(s);
replace if necessary.
− Tighten drain cock(s) fingertight.
•
Drain cock on cup of filter/regulator
unit open.
− Tighten drain screw fingertight.
•
Check valve leaky.
− Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
•
Pressure regulator not opened wide
enough.
− Open pressure regulator more.
•
Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary.
7. Repairs
A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.
8. Environmental protection
A
Danger!
The condensate from the pres-
sure vessel contains oil residue. Dis-
pose of the condensate environmen-
tally safe by taking it to a proper
collecting point!
A
Danger!
Dispose of the pump's crank-
case oil environmetally safe by taking
it to a proper collecting point!
The machine's packaging can be 100 %
recycled.
Worn out devices and accessories con-
cable
when
tain considerable amounts of valuable
raw and plastic materials, which can be
recycled.
stopped
by
ENGLISH
These instructions are printed on paper
produced with elemental chlorine-free
bleaching process.
13