Protocol
Communication medium
Network topology
System bus participants
Max. number of participants
Max. cable length with
CANopen
Baud rate [kbit/s] 10
Max. cable length with
DeviceNet
Baud rate [kbit/s]
Thin cable L [m]
Electrical connection
Electrical connection
DC voltage supply
Insulation voltages the bus system:
é
PE
é
external supply (terminal
39/59)
é
power stage of the 8200
vector
é
control terminals:
é
bus system - external
Ambient temperature
Climatic conditions

Technical data

CANopen or DeviceNet
DIN ISO 11898
Line (terminated at both ends with 120 Ω)
Master or slave
63
Max. possible baud rate depending on bus length:
20
L [m] 5000
2500
Max. possible baud rate depending on bus length:
125
100
Screw terminals, isolated terminal for controller inhibit (CINH)
é
Possible connections
- rigid: 1.5 mm
- flexible without wire crimp cap: 1.0 mm
- flexible with wire crimp cap: 0.5 mm
é
Tightening torques
- 0.5 ... 0.6 Nm (4.4 .. 5.3 lb-in)
internally
(In the event of failure of the controller, the bus system continues
operation)
50 V AC
(mains isolation)
0 V AC
(no mains isolation)
270 V AC (double basic insulation)
0 V AC
(no mains isolation)
0 V AC
(no mains isolation)
during operation:
during transport:
during storage
Class 3K3 to EN 50178 (without condensation, average relative
humidity 85 %)
50
125
1000
550
250
100
2
(AWG 16)
-20 ... +60 °C
-25 ... +70 °C
-25 ... +60 °C
- 8 -
250
500
1000
250
100
25
500
100
2
(AWG 18)
2
(AWG 20)
EDK82ZAFD 1.0