Output function for the analog output
2 options can be selected:
I = 4 ... 20 mA / U = 0 ... 10 V
Setting of the display
4 options can be selected:
°C = display in °Celsius
°F = display in °Fahrenheit
r°C = display in °Celsius (inverted)
r°F = display in °Fahrenheit (inverted)
Calibration offset
The internal measured value (operating value of the sensor) is
offset against the real measured value.
°C
°F
Min-Max memory for system temperature
• Hi: displays the highest measured temperature
• Lo: displays the lowest measured temperature
Erase the memory:
- Press the "Mode/Enter" button until HI or Lo is displayed.
- Press the "Set" button and keep it pressed until "- - -"
is displayed.
- Then press the "Mode/Enter" button briefly.
It is recommended to erase the memory as soon as the unit starts
working under normal operating conditions.
18
All manuals and user guides at all-guides.com
setting range
-9.9 ... +9.9
-17.5 ... +17.5
in steps of
0.1
0.5