Operating Element and Display (Local User Interface)
5.6
Rotating the Screen Display
The IR temperature sensor has an internal orientation sensor. Depending on the orientation of the sensor when
installed the display content is automatically rotated and thus adjusts to the viewer. The orientation sensor is enabled
by default. If desired the orientation sensor can be disabled from the menu. The display orientation can also be set
from the menu (see 11.4 Display Settings on page 27).
5.7
Timeouts
5.7.1
Timeout Display
The display contrast is automatically reduced 2 min after the last time a button was pressed. After 10 min without
pressing a button the display is turned off. Pressing any button turns the display on again. If key lock is enabled, the
contrast is reduced after 2 s without pressing a button, and the display is turned off after 10 s. In alignment mode the
display is turned off after 30 min and teach-in after 10 min.
5.7.2
Timeout Menu
The menu for parameterizing the sensor is automatically exited 1 min after the last time a button is pressed. After
enabling key lock, in alignment mode or teach-in turning off the display automatically returns from the menu.
5.7.3
Overview
Normal
Aligning the sensor
Teach-in
Key lock active
5.8
Indicator LEDs
Display element
LED OUT1 (yellow)
– LED on
– LED off
– LED flashes
LED OUT2 (yellow)
– LED on
– LED off
– LED flashes
LED ON (green)
– LED lights up
– LED off
– LED flashes (ratio t
– LED flashes (ratio 1:1)
5.9
Local User Interface & IO-Link Interface
All parameters which can be set using the buttons can also be set via the IO-Link interface if present. A teach-in can
be performed at the same time only using one of the two interfaces.
14
english
All manuals and user guides at all-guides.com
Menu is terminated
1 min
30 min
10 min
10 s
Function
Temperature threshold digital output 1
Upper switching threshold exceeded
Lower threshold exceeded
Error (see section 14 Error Handing and Display on page 30)
Temperature threshold digital output 2
Upper switching threshold exceeded
Lower threshold exceeded
Error (see section14 Error Handing and Display on page 30)
Power indicator
Sensor ready
Sensor not ready
/t
=9:1)
IO-Link communication
on
off
Error (see section14 Error Handing and Display on page 30)
Display contrast is
Display is turned off
reduced
2 min
10 min
–
30 min
–
10 min
2 s
10 s