d) Area measurement
1. Switch on the device and switch to the area
measurement mode.
2. The following symbol will appear in the top-left
corner of the display:
3. The bottom line of the parallelogram will flash
to indicate that you can measure the length of
the surface.
4. Aim at the point whose distance you want to
measure (length of the surface).
5. Press the MEAS button (3) to measure the
length of the surface.
6. The side line of the parallelogram will flash to indicate that you can measure the width of
the surface.
7. Aim at the point whose distance you want to measure (width of the surface).
8. Press the MEAS button (3) to measure the width of the surface.
9. The area will be calculated and displayed in the measurement field (15).
e) Volume measurement
1. Switch on the device and switch to the volume
measurement mode.
2. The following symbol will appear in the top-left
corner of the display:
3. The bottom line of the cuboid will flash to
indicate that you can measure the length of
the room.
4. Aim at the point whose distance you want to
measure (length of the room).
5. Press the MEAS button (3) to measure the
length of the room.
6. The side line of the cuboid will flash to indicate that you can measure the width of the room.
7. Aim at the point whose distance you want to measure (width of the room).
8. Press the MEAS button (3) to measure the width of the room.
9. The top line of the cuboid will flash to indicate that you can measure the height of the room.
10. Aim at the point whose distance you want to measure (height of the room).
11. Press the MEAS button (3) to measure the height of the room.
12. The volume will be calculated and displayed in the measurement field (15).
f) Indirect distance measurements with 2 points
The indirect measurement of distances on the basis of 2 measurements uses the
Pythagorean theorem. It only functions when one of the two measurement distances
forms a right angle to the distance whose length you wish to measure.
1. Switch on the device and switch to the indirect
measurement mode with 2 points.
2. The following symbol will appear in the top-left
corner of the display:
3. The bottom line of the triangle will flash to
indicate that you can measure the distance to
the first point.
4. Aim at the point at which the desired
measurement distance begins.
5. Press the MEAS button (3) to measure the
distance to the start point.
6. The diagonal line of the triangle will flash to indicate that you can measure the distance to
the second point.
7. Aim at the point at which the desired measurement distance ends.
8. Press the MEAS button (3) to measure the distance to the end point.
9. The distance between the start and end point will be measured and displayed in the
measurement field (15).
Making measurements with the measuring tape
Proceed as follows to make measurements with the measuring tape:
1. Carefully pull the measuring tape on the hook until the desired length is reached. The
measuring tape will lock in the stopping position.
2. Press the lock button (9) to retract the measuring tape.
The hook is magnetic and therefore attaches well to ferromagnetic materials.
The hook is mounted in a movable position to avoid measurement errors. On walls
it is pushed into the inner position, and on edges it is pulled out to the outer position.
This prevents the width of the hook from being added to the measurement.
inner position
outer position
Error codes and troubleshooting
Error code Possible causes
204
Calculation error
220
Low battery
255
The received signal
is too weak or
measurements take
too long
256
The received signal
is too strong
261
Maximum
measurement range
exceeded
500
Hardware error
Cleaning
Do not use any aggressive cleaning agents, rubbing alcohol or other chemical
solutions, as these may damage the housing or impair the functioning of the device.
• Disconnect the device from the power supply before each cleaning session.
• Use a dry, lint-free cloth to clean the product. Do not allow water to get inside the housing.
• To prevent scratch marks, do not press too hard on the surface of the enclosure or display
when cleaning.
Disposal
Electronic devices are recyclable waste and must not be placed in household
waste. At the end of its service life, dispose of the product according to the relevant
statutory regulations. You thus fulfill your statutory obligations and contribute to the
protection of the environment.
Technical data
a) Laser distance meter
Measurement range ............... 40 m
Accuracy .................................± 2 mm
Laser class .............................2
Laser wavelength ...................630–670 nm
Laser power ............................< 1 mW
b) Measuring tape
Measurement range ...............5 m
Accuracy .................................± 2 mm
Width ......................................19 mm
Battery type ............................Li-ion
Battery capacity ......................380 mAh
Operating conditions ............... 0 to +40 °C, 0–90 % relative humidity (non-condensing)
Storage conditions .................. -10 to +60 ºC, 0–95 % relative humidity (non-condensing)
Dimensions (L x W x H) ..........83 x 54 x 79 mm
Weight ....................................290 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming or capture in electronic
data processing systems, requires the prior written approval of the publisher. Reprinting, also in part, is prohibited. This
publication reflects the technical status at the time of printing.
Copyright 2020 by Conrad Electronic SE.
Suggested solution
Repeat the measurement in accordance with the
steps in these instructions
Charge the battery
Improve the reflectivity of the surface (use flat
surfaces or white paper as a target).
Avoid backlight
Improve the reflectivity of the surface (use flat
surfaces as a target or avoid pointing the laser beam
at strong light sources).
Observe the maximum measurement range (up to
40 m)
Switch the device off and back on again, and repeat
if necessary
If the error is still displayed after several attempts,
contact a dealer or specialist workshop.
*2303985_v1_1220_02_DS_m_(1)_4L