Ele c tric a l c o n n e c tio n o f yo u r h o b
· Be fore proce e ding with the e le ctrica l conne ction, ve rify tha t the curre nt
carrying capacity of the system and the socket is adequate for the maximum
powe r ra ting of the hob.
· Ele ctrica l ins ta lla tion of the re s ide nce a nd the e le ctrica l curre nt plug in
us e mus t be e a rthe d a nd conform with s a fe ty re gula tions .
· If the re is no de dica te d hob circuit a nd fus e d s witch, the y mus t be ins ta lle d
by a qua lifie d e le ctricia n be fore the hob is conne cte d.
· The fus e d s witch mus t be e a s ily a cce s s ible once the hob ha s be e n
ins ta lle d.
· Do not us e a da ptors , multiple s ocke ts a nd/or e xte ns ion le a ds .
· This a pplia nce conforms with the re quire me nts ofthe following EEC
Dire ctive s :
1. Vitroce ra mic hob EEC/73/23 a nd 93/68, EEC/89/336 re la ting to
ra dio inte rfe re nce ,
2. EEC/89/109 re la ting to conta ct with foods .
· A circuit bre a ke r with a conta ct ope ning of a t le a s t 3 mm, ra te d 32A a nd
de la ye d functioning type mus t be ins ta lle d in the s upply circuit.
3x2,5 mm² 220V~
3x2,5 mm² 230V~
3x2,5 mm² 240V~
Supply cable connection can be differ according to terminal box type.
· The s upply ca ble mus t be H05VV-F 3X2,5 mm² / 60227 IEC 53. You will
find the conne ction dia gra m s hown on the ba ck of your a pplia nce .
· During installation, please insure that isolated cables are used. An incorrect
conne ction might da ma ge your a pplia nce . The gua ra nte e will not cove r
s uch da ma ge s .
· All re pa irs mus t be ca rrie d out by a n a uthoris e d s e rvice pe rs ona l or a
qua lifie d e le ctricia n.
· Unplug your a pplia nce be fore e a ch ma inte na nce . For re conne ction, follow
the conne ction dia gra ms .
ELEC TRIC AL C O NNEC TIO N
/
5x1.5 mm² 380V 3N~
3x2,5 mm² 220V~
5x1.5 mm² 400V 3N~
3x2,5 mm² 230V~
5x1.5 mm² 415V 3N~
3x2,5 mm² 240V~
5x1.5 mm² 380V 3N~
5x1.5 mm² 400V 3N~
5x1.5 mm² 415V 3N~