14
7.2 Setting ranges of the switch points or switch back points
Operational
scanning
range
280 mm
480 mm
1600 mm
E
4000 mm
6400 mm
* The increment for all units is 1 cm or 1 inch.
The maximum setting ranges are given. The setting of the "bot" and "top" parameters
determines how the setting ranges are reduced.
0
top
bot – top
> 3 units* *
bot
* 1 unit
= 1 cm or. 1 inch, when setting the maximum measuring range (bot – top)
= 1 cm, 1 inch or, otherwise, 1 %
Version: 06.10.2014
All manuals and user guides at all-guides.com
SP1, SP2, FH1,
FH2 *
2 .. 32 cm
2 .. 13 inch
2 .. 59 cm
2 .. 23 inch
2 .. 180 cm
2 .. 71 inch
2 .. 465 cm
2 .. 183 inch
2 .. 740 cm
2 .. 291 inch
Blind
Maximum scanning
range
HYDAC ELECTRONIC GMBH
RP1, RP2, FL1,
FL2*
1 .. 31 cm
1 .. 12 inch
1 .. 58 cm
1 .. 22 inch
1 .. 179 cm
1 .. 70 inch
1 .. 464 cm
1 .. 182 inch
1 .. 739 cm
1 .. 290 inch
N
Maximum level
max
SP
SP (FH)
RP (FL)
RP (FL)
SP (FH)
SP
RP (FL)
RP (FL)
0
Minimum level
HNS 526
= N
max
max
= N
– 1 unit*
max
max
= 2 units *
min
= 1 unit *
min
Part No.: 669869