Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Basic Safety Instructions; Maintenance Schedule; Maintenance Work - Storch Multisprayer MS 10 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

9. Maintenance

9.1 Basic safety information
Caution: Always disconnect the mains plug from the electric circuit before maintenance!
-
The installation and use of spare parts and accessories not sourced from the device manufacturer is pro-
hibited!
-
The maintenance intervals must be complied with.
-
Changing operating parameters and components is prohibited.

9.2 Maintenance schedule

-
Change pump oil every 300 hours of full operation or once a year.
-
Annual inspection of equipment safety in accordance with DGUV V3 by a qualified person (electrician).

9.3 Maintenance work

9.3.1 Oil level

-
The oil level must be up to the oil level mark (Fig. 4) on the filler neck.

9.3.2 Oil change

-
Open the oil filler neck (e), turn device upside down, and let the oil run into a suitable container.
-
Fill with new oil up to the outer oil level mark (Fig. 4).
-
Oil grade.: Hydraulic oil Unysin CLP 150, approx. 100 ml
-
Used oil must be handed over to a suitable disposal company or at a used oil collection point.
Fig. 4
Translation of the original instruction
Fig. 5
68

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis