Installation
1. After completition of the wall surface and installation
of the take off fittings, the grey flushing unit must be
removed and the box has to be shortened approx.
1 - 2 mm to the front edge of the tiles.
2. Seal with silicone. When used in hollow wall
installation seal the edge to the gipsom board.
3. Put on the installation unit (cold water mark up right
hand side), sleeve, cover plate and adapter shaft. 4.
Mount setting knob in position 38° and tighten
screw.
Adjustment
Correction is necessary if the temperature measured at
the take off point differs from the temperature set on the
scale. To adjust temperature proceed as follows: Turn
the setting knob until water at a temperature of 38° C
comes out of the outlet. Loosen screw of setting knob.
Remove setting knob and turn to the 38° C position.
Attach setting knob again and tighten its screw.
4
English
Temperature limitation
The temperature range is limited by the safety check to
38° C. If a higher temperature is required, it is possible
to override the 38° C check by depressing the red safety
button.
Maintenance
The shut-off valves are automatically closed by removing
the none return valves.
Put setting knob to 38° C and hold in position.
Undo screw and pull off setting knob.
Remove cover plate (velcro straps) holder for cover plate
1 0
and seal.
Activate hand shower.
By activated hand shower unscrew both none return
valves by alternately turning them counter clockwise,
after ca. 3 ½ turns the shut-off valves are closed.
Check and clean filters.
7 2
- 1 0
0
0
2 2