Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Data - Gemü Q50 eSyStep Betriebsanleitung

Elektromotorisch betätigtes schlauchquetschventil
Vorschau ausblenden Andere Handbücher für Q50 eSyStep:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6 Technical data
6.6 Actuator's duty cycle and service life
If there is inadequate force to compress the tube, the force of the actuator can be adapted via the IO-Link using the config files.
Service life:
Duty cycle:
▶ The specified characteristics and values apply to the factory setting.
▶ With reduced forces, higher duty cycles and/or higher ambient temperatures are possible. At higher force settings the duty
cycle and/or ambient temperature is reduced.
▶ IO-Link: Index 0x90 - Subindex 2 - Force

6.7 Electrical data

Supply voltage Uv:
Rating:
Operation:
Reverse battery protec-
tion:
6.7.1 Digital input signals
Inputs:
Input voltage:
Logic level "1":
Logic level "0":
Input current:
6.7.2 Digital output signals
Outputs:
Type of contact:
Switching voltage:
Switching current:
GEMÜ Q50 eSyStep
At least 500,000 switching cycles at room temperature and permissible duty cycle.
Control module – Open/Close control (code A5, A6, AE)
Duty cycle at full valve stroke and 10 minutes cycle time.
100
90
80
70
60
50
40
30
Pinch valve
20
10
0
0
10
20
Ambient temperature [°C]
24 V DC ± 10%
Actuator size 0 (code 0A)
Stepper motor, self-locking
Yes
Function selectable via IO-Link (see table Overview of available functions – Input and output sig-
nals)
24 V DC
> 15.3 V DC
< 5.8 V DC
typically < 0.5 mA
Function selectable via IO-Link (see table Overview of available functions – Input and output sig-
nals)
Push-Pull
Power supply Uv
≤ 140 mA
30
40
50
60
70
NOTICE
20 W
58 / 100
80
www.gemu-group.com